Optical matching of near infrared reflectance monochromator instruments for the analysis of ground and whole wheat

被引:14
作者
Osborne, BG
Kotwal, Z
Wesley, IJ
Saunders, L
Dardenne, P
Shenk, JS
机构
[1] BRI Australia Ltd, N Ryde, NSW 1670, Australia
[2] CSIRO, Grain Qual Res Lab, N Ryde, NSW 1670, Australia
[3] Foss NIRSyst Asia Pacific, Oatley, NSW 2223, Australia
[4] Ctr Rech Agron Gembloux, B-5030 Gembloux, Belgium
[5] Infrasoft Int Inc, Port Matilda, PA 16870 USA
关键词
monochromator; NIR; reflectance; standardisation; calibration transfer; wheat; whole grain;
D O I
10.1255/jnirs.247
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Eight near infrared (NIR) reflectance monochromator instruments in Australia have been optically matched (standardised) in order that reflectance spectra can be obtained when the same sample is measured on any of the instruments which are as similar as reflectance spectra obtained by re-packing the same sample on one instrument. This means that data from the different instruments can be merged to produce calibrations based on a larger number of more diverse samples than would be available to any one laboratory, without the need for the actual samples to be moved around the country. In turn, the resulting spectral library and calibrations can be shared. Two methods of standardisation of this type of instrument have been previously reported for ground samples. One method utilises 30 sealed powdered samples of diverse types in order to correct for both slope and bias while the other requires only a single sealed sample to correct for bias. The results of standardisation, using the set of 30 samples and using a single ground wheat, confirms that the single sample standardisation works as well as that performed using the 30 samples. In addition, an extension of the single sample method using whole grain samples is reported. The results confirm that the single sample method can be successfully used to optically match NIR reflectance monochromator instruments of the same brand.
引用
收藏
页码:167 / 178
页数:12
相关论文
共 13 条
[1]  
BISTON R, 1990, P 2 INT NEAR INFR SP, P100
[2]  
DARDENNE P, 1992, NEAR INFRARED SPECTR
[3]  
DARDENNE P, 1991, P 3 INT C NEAR INFR, P655
[4]   Portability of near infrared spectroscopic calibrations for petrochemical parameters [J].
Hoffmann, U ;
Zanier-Szydlowski, N .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 1999, 7 (01) :33-45
[5]  
OSBORNE B, 1997, NIR NEWS, V8, P10
[6]  
Shenk J. S., 1997, J NEAR INFRARED SPEC, V5, P223
[7]   NEAR-INFRARED REFLECTANCE ANALYSIS WITH SINGLE-PRODUCT AND MULTIPRODUCT CALIBRATIONS [J].
SHENK, JS ;
WESTERHAUS, MO .
CROP SCIENCE, 1993, 33 (03) :582-584
[8]   CALIBRATION TRANSFER BETWEEN NEAR-INFRARED REFLECTANCE SPECTROPHOTOMETERS [J].
SHENK, JS ;
WESTERHAUS, MO ;
TEMPLETON, WC .
CROP SCIENCE, 1985, 25 (01) :159-161
[9]   USING NEAR-INFRARED REFLECTANCE PRODUCT LIBRARY FILES TO IMPROVE PREDICTION ACCURACY AND REDUCE CALIBRATION COSTS [J].
SHENK, JS ;
FALES, SL ;
WESTERHAUS, MO .
CROP SCIENCE, 1993, 33 (03) :578-581
[10]   POPULATION DEFINITION, SAMPLE SELECTION, AND CALIBRATION PROCEDURES FOR NEAR-INFRARED REFLECTANCE SPECTROSCOPY [J].
SHENK, JS ;
WESTERHAUS, MO .
CROP SCIENCE, 1991, 31 (02) :469-474