Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part II - selected sensor test results

被引:86
作者
Boon-Brett, L. [1 ]
Bousek, J. [1 ,2 ]
Moretto, P. [1 ]
机构
[1] European Commiss, DG Joint Res Ctr, Inst Energy, Cleaner Energy Unit, NL-1755 ZG Petten, Netherlands
[2] Brno Univ Technol, Fac Elect Engn & Commun, Brno 60200, Czech Republic
关键词
Hydrogen sensor; Hydrogen detection; Safety; Sensor performance testing;
D O I
10.1016/j.ijhydene.2008.10.033
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Reliable hydrogen sensors are essential to detect accidental hydrogen releases when hydrogen will be used to fuel future vehicles. To assess the performance of hydrogen safety sensors under conditions typical of automotive applications a test protocol has been defined. It has been experimentally evaluated by performing tests on commercially available hydrogen sensors. Catalytic sensors measured hydrogen concentration accurately and sensor response was largely independent of ambient parameters. However they were significantly cross sensitive to carbon monoxide and the detection limit was high. metal-oxide semiconductive sensors had a low detection limit and showed a low cross sensitivity to carbon monoxide however almost all of these samples showed poor accuracy and a strong dependence on ambient parameters. Electrochemical sensors also had a low detection limit however ambient parameters, cross sensitivity and accuracy tests showed a high variation in results. Tests on a limited number of thermal conductivity sensors highlighted their high detection limit and strong dependence on temperature. (C) 2008 International Association for Hydrogen Energy. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:562 / 571
页数:10
相关论文
共 20 条
[1]   Sol-gel derived thin-film semiconductor hydrogen gas sensor [J].
Adamyan, A. Z. ;
Adamyan, Z. N. ;
Aroutiounian, V. M. ;
Arakelyan, A. H. ;
Touryan, K. J. ;
Turner, J. A. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (16) :4101-4108
[2]  
[Anonymous], 2003, CRC Handbook of Chemistry and Physics, V84th
[3]  
Arndt M., 2001, P SENS 2001 NURNB 8, P541
[4]   A first principles model of metal oxide gas sensors for measuring combustibles [J].
Brailsford, AD ;
Yussouff, M ;
Logothetis, EM .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 49 (1-2) :93-100
[5]  
BRETT L, RELIABILITY COMMER 1
[6]  
DIMEO F, 2006, SENSORS ACTUATORS B, V117
[7]   Hydrogen sensor for molten metals usable up to 1500 K [J].
Fukatsu, N ;
Kurita, N ;
Koide, K ;
Ohashi, T .
SOLID STATE IONICS, 1998, 113 :219-227
[8]  
HUNTER GW, 1992, 106141 NASA
[9]  
JOUHANNAUD J, 2007, J PHYS C SER, V76
[10]   Study on the response and recovery properties of semiconductor gas sensors using a high-speed gas-switching system [J].
Kida, Tetsuya ;
Kuroiwa, Toru ;
Yuasa, Masayoshi ;
Shimanoe, Kengo ;
Yamazoe, Noboru .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) :928-933