Evaluation of the FACScount, TRAx CD4 and Dynabeads methods for CD4 lymphocyte determination

被引:46
作者
Lyamuya, EF
Kagoma, C
Mbena, EC
Urassa, WK
Pallangyo, K
Mhalu, FS
Biberfeld, G
机构
[1] UNIV DAR ES SALAAM,COLL HLTH SCI,MUHIMBILI UNIV,DEPT IMMUNOL MICROBIOL,DAR ES SALAAM,TANZANIA
[2] UNIV DAR ES SALAAM,COLL HLTH SCI,MUHIMBILI UNIV,DEPT MED,DAR ES SALAAM,TANZANIA
[3] KAROLINSKA INST,SWEDISH INST INFECT DIS CONTROL,S-10521 STOCKHOLM,SWEDEN
[4] KAROLINSKA INST,CTR MICROBIOL & TUMOR BIOL,S-10521 STOCKHOLM,SWEDEN
关键词
T lymphocyte subset; immunophenotyping; alternative method; Africa;
D O I
10.1016/0022-1759(96)00094-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A study to evaluate the performance of the FACScount, TRAx CD4 and Dynabeads methods for the determination of CD4(+) T lymphocyte subset levels was conducted in Tanzania as part of a World Health Organization (WHO) collaborative multicenter field evaluation of alternative methodologies for the enumeration of CD4(+) T lymphocytes. The objective was to compare the performance of these alternative methods in a developing country setting, against that of flow cytometry as the reference standard. T lymphocyte subset levels were determined in 91 HIV seronegative and 98 HIV-1 seropositive adults using the three alternative methods. CD4(+) and CD8(+) T lymphocyte counts were determined by all methods except for TRAx CD4 enzyme linked immunosorbent assay (ELISA) which measures CD4(+) T lymphocyte levels only, Linear regression analysis was done to correlate the counts obtained by the alternative methods to those obtained by flow cytometry, The overall correlation coefficients of FACScount and Dynabeads CD4(+) and CD8(+) T lymphocyte counts with those of flow cytometry were high (r > 0.9). A lower correlation (r = 0.631) was obtained when TRAx CD4(+) ELISA counts were compared to those of the reference method, These results show that two of these alternative methodologies are suitable for the determination of CD4(+) and CD8(+) T lymphocyte counts with the use of African blood samples, Since the methods are simpler and cheaper than flow cytometry, they provide an alternative option for the enumeration of T lymphocyte subsets in laboratories with limited facilities.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 17 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] BREDBERGRADEN U, 1995, J ACQ IMMUN DEF SYND, V8, P182
  • [3] Dabis F, 1995, AIDS, V9 Suppl A, pS67
  • [4] DECLINE IN CD4+ CELL NUMBERS REFLECTS INCREASE IN HIV-1 REPLICATION
    DEWOLF, F
    ROOS, M
    LANGE, JMA
    HOUWELING, JTM
    COUTINHO, RA
    VANDERNOORDAA, J
    SCHELLEKENS, PT
    GOUDSMIT, J
    [J]. AIDS RESEARCH AND HUMAN RETROVIRUSES, 1988, 4 (06) : 433 - 440
  • [5] QUALITY-CONTROL IN THE FLOW CYTOMETRIC MEASUREMENT OF LYMPHOCYTE-T SUBSETS - THE MULTICENTER AIDS COHORT STUDY EXPERIENCE
    GIORGI, JV
    CHENG, HL
    MARGOLICK, JB
    BAUER, KD
    FERBAS, J
    WAXDAL, M
    SCHMID, I
    HULTIN, LE
    JACKSON, AL
    PARK, L
    TAYLOR, JMG
    [J]. CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1990, 55 (02): : 173 - 186
  • [6] PRECISION AND ACCURACY OF ABSOLUTE LYMPHOCYTE COUNTS
    KOEPKE, JA
    LANDAY, AL
    [J]. CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1989, 52 (01): : 19 - 27
  • [7] APPLICATION OF FLOW-CYTOMETRY TO THE STUDY OF HIV-INFECTION
    LANDAY, A
    OHLSSONWILHELM, B
    GIORGI, JV
    [J]. AIDS, 1990, 4 (06) : 479 - 497
  • [8] LOUA A, 1994, ANN SOC BELG MED TR, V74, P61
  • [9] RISK-FACTORS FOR VERTICAL TRANSMISSION OF HIV-1 AND EARLY MARKERS OF HIV-1 INFECTION IN CHILDREN
    NEWELL, ML
    PECKHAM, C
    [J]. AIDS, 1993, 7 : S91 - S97
  • [10] EVALUATION OF ALTERNATIVE CD4 TECHNOLOGIES FOR THE ENUMERATION OF CD4 LYMPHOCYTES
    NICHOLSON, JKA
    VELLECA, WM
    JUBERT, S
    GREEN, TA
    BRYAN, L
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 177 (1-2) : 43 - 54