Clinical complications of osseointegrated implants

被引:442
作者
Goodacre, CJ [1 ]
Kan, JYK [1 ]
Rungcharassaeng, K [1 ]
机构
[1] Loma Linda Univ, Sch Dent, Off Dean, Dept Restorat Dent, Loma Linda, CA 92350 USA
关键词
D O I
10.1016/S0022-3913(99)70208-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. There is no comprehensive review of the literature that identifies the complications reported in clinical dental implant studies. Purpose. This article attempted to determine the types of complications that have been reported and to provide data regarding their frequency. Methods. All available clinical studies from 1981 to 1997, published in English or with English abstract, that presented success/failure data regarding implant treatment were evaluated to determine the types of reported complications and to quantify implant loss as it relates to type of prosthesis, arch, time, implant length, and bone quality. Results. Greater implant loss occurred with overdentures than with other types of prostheses. There was greater loss in the maxilla than mandible with fixed complete dentures and overdentures, whereas little arch difference was noted with fixed partial dentures. Implant loss increased with short implants and poor bone quality. The time of implant loss (preprosthetic vs postprosthetic) varied with type of prosthesis. Surgical complications included neurosensory disturbance, hematoma, mandibular fracture, hemorrhage, and tooth devitalization. Initial and long-term marginal bone changes were identified. Peri-implant soft tissue complications included dehiscence, fistulas, and gingival inflammadon/proliferation. Mechanical complications were screw loosening/fracture, implant fractures, framework, resin base and veneering material fractures, opposing prosthesis fractures, and overdenture mechanical retention problems. Some studies also presented phonetic and esthetic complications. Conclusions. Although the literature presents considerable information on implant complications, variations in study design and reporting procedures limited the available data and therefore precluded proper analysis of certain complications.
引用
收藏
页码:537 / 552
页数:16
相关论文
共 96 条
[1]   MARGINAL TISSUE-REACTIONS AT OSSEOINTEGRATED TITANIUM FIXTURES .1. A 3-YEAR LONGITUDINAL PROSPECTIVE-STUDY [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI ;
LINDHE, J ;
ERIKSSON, B ;
SBORDONE, L .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1986, 15 (01) :39-52
[2]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[3]  
ADELL R, 1985, TISSUE INTEGRATED PR, P175
[4]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[5]   OSSEOINTEGRATED ORAL IMPLANTS - A SWEDISH MULTICENTER STUDY OF 8139 CONSECUTIVELY INSERTED NOBELPHARMA IMPLANTS [J].
ALBREKTSSON, T ;
DAHL, E ;
ENBOM, L ;
ENGEVALL, S ;
ENGQUIST, B ;
ERIKSSON, AR ;
FELDMANN, G ;
FREIBERG, N ;
GLANTZ, PO ;
KJELLMAN, O ;
KRISTERSSON, L ;
KVINT, S ;
KONDELL, PA ;
PALMQUIST, J ;
WERNDAHL, L ;
ASTRAND, P .
JOURNAL OF PERIODONTOLOGY, 1988, 59 (05) :287-296
[6]   A MULTICENTER REPORT ON OSSEOINTEGRATED ORAL IMPLANTS [J].
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 60 (01) :75-84
[7]   Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital [J].
Allen, PF ;
McMillan, AS ;
Smith, DG .
BRITISH DENTAL JOURNAL, 1997, 182 (08) :298-302
[8]  
Andersson B, 1995, Int J Oral Maxillofac Implants, V10, P702
[9]  
ASTRAND P, 1991, International Journal of Oral and Maxillofacial Implants, V6, P305
[10]  
Avivi-Arber L, 1996, Int J Oral Maxillofac Implants, V11, P311