Between-day reliability of a method for non-invasive estimation of muscle composition

被引:105
作者
Simunic, Bostjan [1 ]
机构
[1] Univ Primorska, Sci & Res Ctr Koper, Inst Kinesiol Res, Koper, Slovenia
关键词
Skeletal muscle; Tensiomyography; Repeatability; Validity; FORCE; ACCELEROMETER; PARAMETERS; RESPONSES; FIBERS;
D O I
10.1016/j.jelekin.2012.04.003
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
Tensiomyography is a method for valid and non-invasive estimation of skeletal muscle fibre type composition. The validity of selected temporal tensiomyographic measures has been well established recently; there is, however, no evidence regarding the method's between-day reliability. Therefore it is the aim of this paper to establish the between-day repeatability of tensiomyographic measures in three skeletal muscles. For three consecutive days, 10 healthy male volunteers (mean +/- SD: age 24.6 +/- 3.0 years; height 177.9 +/- 3.9 cm; weight 72.4 +/- 5.2 kg) were examined in a supine position. Four temporal measures (delay, contraction, sustain, and half-relaxation time) and maximal amplitude were extracted from the displacement-time tensiomyogram. A reliability analysis was performed with calculations of bias, random error, coefficient of variation (CV), standard error of measurement, and intra-class correlation coefficient (ICC) with a 95% confidence interval. An analysis of ICC demonstrated excellent agreement (ICC were over 0.94 in 14 out of 15 tested parameters). However, lower CV was observed in half-relaxation time, presumably because of the specifics of the parameter definition itself. These data indicate that for the three muscles tested, tensiomyographic measurements were reproducible across consecutive test days. Furthermore, we indicated the most possible origin of the lowest reliability detected in half-relaxation time. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:527 / 530
页数:4
相关论文
共 34 条
[1]
[Anonymous], 1990, ADV EXTERNAL CONTROL
[2]
[Anonymous], 2010, ANN KINESIOLOGIAE
[3]
ACOUSTIC MYOGRAPHY - A NONINVASIVE MONITOR OF MOTOR UNIT FATIGUE [J].
BARRY, DT ;
GEIRINGER, SR ;
BALL, RD .
MUSCLE & NERVE, 1985, 8 (03) :189-194
[4]
Properties of musculus gluteus maximus in above-knee amputees [J].
Burger, H ;
Valencic, V ;
Marincek, C ;
Kogovsek, N .
CLINICAL BIOMECHANICS, 1996, 11 (01) :35-38
[5]
Spatial fiber type distribution in normal human muscle - Histochemical and tensiomyographical evaluation [J].
Dahmane, R ;
Djordjevic, S ;
Simunic, B ;
Valencic, V .
JOURNAL OF BIOMECHANICS, 2005, 38 (12) :2451-2459
[6]
Evaluation of the ability to make non-invasive estimation of muscle contractile properties on the basis of the muscle belly response [J].
Dahmane, R ;
Valencic, V ;
Knez, N ;
Erzen, I .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (01) :51-55
[7]
Adaptive potential of human biceps femoris muscle demonstrated by histochemical, immunohistochemical and mechanomyographical methods [J].
Dahmane, Raja ;
Djordjevic, Srdjan ;
Smerdu, Vika .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (11) :999-1006
[8]
The effectiveness of two novel techniques in establishing the mechanical and contractile responses of biceps femoris [J].
Ditroilo, Massimiliano ;
Hunter, Angus M. ;
Haslam, Samuel ;
De Vito, Giuseppe .
PHYSIOLOGICAL MEASUREMENT, 2011, 32 (08) :1315-1326
[9]
Variation in the determinants of power of chemically skinned human muscle fibres [J].
Gilliver, S. F. ;
Degens, H. ;
Rittweger, J. ;
Sargeant, A. J. ;
Jones, D. A. .
EXPERIMENTAL PHYSIOLOGY, 2009, 94 (10) :1070-1078
[10]
Grabljevec K, 2002, REHABILITACIJA, V1, P16