Enzyme microgels in packed-bed bioreactors with downstream amperometric detection using microfabricated interdigitated microsensor electrode arrays

被引:52
作者
Guiseppi-Elie, A
Sheppard, NF
Brahim, S
Narinesingh, D
机构
[1] Virginia Commonwealth Univ, Dept Chem Engn, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Ctr Bioelect Biosensors & Biochips, Richmond, VA 23284 USA
[3] MicroCHIPS Inc, Cambridge, MA USA
[4] Univ W Indies, Dept Chem, St Augustine, Trinidad Tobago
关键词
hydrogels; amperometry; glucose oxidase; glutamate oxidase; glucose; monosodium glutamate; interdigitated microsensor electrode arrays;
D O I
10.1002/bit.10069
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this article, we describe the use of pH-responsive hydrogels as matrices for the immobilization of two enzymes, glucose oxidase (GOx) and glutamate oxidase (GlutOx). Spherical hydrogel beads were prepared by inverse suspension polymerization and the enzymes were immobilized by either physical entrapment or covalent immobilization within or on the hydrogel surface. Packed-bed bioreactors were prepared containing the bioactive hydrogels and these incorporated into flow injection (Fl) systems for the quantitation of glucose and monosodium glutamate (MSG) respectively. The Fl amperometric detector comprised a microfabricated Interdigitated array within a thin-layer flow cell. For the Fl manifold incorporating immobilized GOx, glucose response curves were found to be linear over the concentration range 1.8-280 my dL(-1) (0.1-15.5 mM) with a detection limit of 1.4 mg dL(-1) (0.08 mM). Up to 20 samples can be manually analyzed per hour, with the hydrogel-GOx bioreactor exhibiting good within-day (0-19%) precision. The optimized Fl manifold for MSG quantitation yielded a linear response range of up to 135 mg dL(-1) (8 mM) with a detection limit of 3.38 mg dL(-1) (0.2 mM) and a throughput of 30 samples h(-1). Analysis of commercially produced soup samples gave a within-day precision of 3.6%. Bioreactors containing these two physically entrapped enzymes retained > 60% of their initial activities after a storage period of up to 1 year. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 25 条
  • [1] [Anonymous], ELECT IMPEDANCE PROP
  • [2] [Anonymous], 2004, J CONTROL RELEASE, DOI DOI 10.1016/j.jconrel.2003.12.025
  • [3] IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLY(2-HYDROXYETHYL METHACRYLATE) MEMBRANES
    ARICA, Y
    HASIRCI, VN
    [J]. BIOMATERIALS, 1987, 8 (06) : 489 - 495
  • [4] FLOW KINETICS OF L-ASPARAGINASE ATTACHED TO NYLON TUBING
    BUNTING, PS
    LAIDLER, KJ
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1974, 16 (01) : 119 - 134
  • [5] TARGETING OF N-(2-HYDROXYPROPYL)METHACRYLAMIDE CO-POLYMERS TO LIVER BY INCORPORATION OF GALACTOSE RESIDUES
    DUNCAN, R
    KOPECEK, J
    REJMANOVA, P
    LLOYD, JB
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1983, 755 (03) : 518 - 521
  • [6] MASS-TRANSFER IN PH-SENSITIVE HYDROGELS
    GEHRKE, SH
    CUSSLER, EL
    [J]. CHEMICAL ENGINEERING SCIENCE, 1989, 44 (03) : 559 - 566
  • [7] IMMOBILIZED ENZYME CHEMICALLY MODIFIED ELECTRODE AS AN AMPEROMETRIC SENSOR
    IANNIELLO, RM
    YACYNYCH, AM
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (13) : 2090 - 2095
  • [8] STIMULI SENSITIVE POLYMERS FOR DRUG DELIVERY SYSTEMS
    KWON, IC
    BAE, YH
    OKANO, T
    BERNER, B
    KIM, SW
    [J]. MAKROMOLEKULARE CHEMIE-MACROMOLECULAR SYMPOSIA, 1990, 33 : 265 - 277
  • [9] DUAL-ANALYTE FIBEROPTIC SENSOR FOR THE SIMULTANEOUS AND CONTINUOUS MEASUREMENT OF GLUCOSE AND OXYGEN
    LI, L
    WALT, DR
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (20) : 3746 - 3752
  • [10] KINETICS OF CARBOXYMETHYLCELLULOSE-FICIN IN PACKED BEDS
    LILLY, MD
    HORNBY, WE
    CROOK, EM
    [J]. BIOCHEMICAL JOURNAL, 1966, 100 (03) : 718 - &