A Magneto-Inductive Sensor Based Wireless Tongue-Computer Interface

被引:135
作者
Huo, Xueliang [1 ]
Wang, Jia [2 ]
Ghovanloo, Maysam [1 ]
机构
[1] Georgia Inst Technol, Dept Elect & Comp Engn, GT Bion Lab, Atlanta, GA 30308 USA
[2] N Carolina State Univ, Dept Elect & Comp Engn, NC Bion Lab, Raleigh, NC 27695 USA
关键词
Assistive technologies (ATs); environment control; information transfer rate (ITR); magneto-inductive sensors; tongue-computer interfacing; tongue motion;
D O I
10.1109/TNSRE.2008.2003375
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a noninvasive, unobtrusive magnetic wireless tongue-computer interface, called "Tongue Drive," to provide people with severe disabilities with flexible and effective computer access and environment control. A small permanent magnet secured on the tongue by implantation, piercing, or tissue adhesives, is utilized as a tracer to track the tongue movements. The magnetic field variations inside and around the mouth due to the tongue movements are detected by a pair of three-axial linear magneto-inductive sensor modules mounted bilaterally on a headset near the user's cheeks. After being wirelessly transmitted to a portable computer, the sensor output signals are processed by a differential field cancellation algorithm to eliminate the external magnetic field interference. and translated into user control commands. which could then be used to access a desktop computer, maneuver a powered wheelchair, or control other devices in the user's environment. The system has been successfully tested on six able-bodied subjects for computer access by defining six individual commands to resemble mouse functions. Results show that the Tongue Drive system response time for 87% correctly completed commands is 0.8 s, which yields to an information transfer rate of similar to 130 b/min.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 34 条
[1]   Targeting recovery: Priorities of the spinal cord-injured population [J].
Anderson, KD .
JOURNAL OF NEUROTRAUMA, 2004, 21 (10) :1371-1383
[2]   System for assisted mobility using eye movements based on electrooculography [J].
Barea, R ;
Boquete, L ;
Mazo, M ;
López, E .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2002, 10 (04) :209-218
[3]  
BOUKHENOUFA A, 2005, IEEE SENS J, V5, P2594
[4]  
Chen Y L, 1999, IEEE Trans Rehabil Eng, V7, P474, DOI 10.1109/86.808951
[5]  
COHEN A, 1988, BIOMED SIGNAL PROCES, V2, P63
[6]  
*COMP LTD, JOUSE2
[7]  
Cook A. M., 2019, Assistive technologies: principles and practice, V5th
[8]  
Duda R., 2001, PATTERN CLASSIFICATI, P174
[9]  
FOX J, 1997, APPL REGRESSION ANAL, P98
[10]   Tongue operated assistive technologies [J].
Ghovanloo, Maysam .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :4376-4379