Blood loss from blood sample removals in intensive care. A preliminary study.

被引:23
作者
Alazia, M
Colavolpe, JC
Botti, G
Corda, N
Ramero, C
Francois, G
机构
来源
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION | 1996年 / 15卷 / 07期
关键词
intensive care; ICU; phlebotomy; blood transfusion; anaemia; blood;
D O I
10.1016/S0750-7658(96)89468-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To assess the volume of blood samples withdrawn for laboratory testing in intensive care unit (ICU) patients and to determine the influence of the resulting blood loss on transfusion requirements in patients staying in the ICU for more than seven days. Study design: Prospective clinical open study. Patients: Fifty patients treated in the ICU over the 3-month study period, neither admitted for a systematic postoperative monitoring. nor experiencing bleeding or haemolysis. Methods: For each patient the following data were obtained. duration of ICU stay. volume or the daily withdrawn blood, the concentration of haemoglobin (Hb) at the time or ICU admission. ICU discharge and before each transfusion, volume of transfused blood. Results: A mean volume of 62 +/- 29 mL d(-1) of blood was taken. it decreased from 85 +/- 6 mL on admission day, to 66 +/- 6 mL after seven days and 60 +/- 8 mL after 14 days. About 27% of the withdrawn blood was rejected (initial blood reflowing through cannula and connection tube). Twenty-one patients (42%) had a length of stay greater than 7 days. In this population, a first group (13/21) was given transfusions of packed red cells during their hospitalisation and a second group (8/21) was not transfused. The mean volume of blood taken per day (67 +/- 21 mL d(-1) vs 55 +/- 15 mL d(-1)) and the total volume (1.204 +/- 810 mL vs 810 +/- 389 mL) were not significantly higher in the transfused group. Conversely the mean haemoglobin concentration on ICU admission ( 97 +/- 22 g L(-1) vs 136 +/- 26 g L(-1)) was significantly lower (P = 0.001) in the transfused patients. Conclusion: Blood losses from blood withdrawal for laboratory tests are important and In agreement with the results of other reports. It is generally accepted that iatrogenic blood loss of this magnitude can cause anaemia if repeated over a prolonged period. Conversely, our data suggest that brood sampling does not contribute significantly to anaemia and transfusion requirements in patients with a prolonged ICU stay.
引用
收藏
页码:1004 / 1007
页数:4
相关论文
共 13 条
  • [1] RBC TRANSFUSION IN THE ICU - IS THERE A REASON
    CORWIN, HL
    PARSONNET, KC
    GETTINGER, A
    [J]. CHEST, 1995, 108 (03) : 767 - 771
  • [2] NOSOCOMIAL ANEMIA
    EYSTER, E
    BERNENE, J
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1973, 223 (01): : 73 - 74
  • [3] EFFECTIVE MEASURES FOR REDUCING BLOOD-LOSS FROM DIAGNOSTIC LABORATORY TESTS IN INTENSIVE-CARE UNIT PATIENTS
    FOULKE, GE
    HARLOW, DJ
    [J]. CRITICAL CARE MEDICINE, 1989, 17 (11) : 1143 - 1145
  • [4] IATROGENIC ANEMIA
    HENRY, ML
    GARNER, WL
    FABRI, PJ
    [J]. AMERICAN JOURNAL OF SURGERY, 1986, 151 (03) : 362 - 363
  • [5] ERYTHROPOIETIN RESPONSE TO CRITICAL ILLNESS
    KRAFTEJACOBS, B
    LEVETOWN, ML
    BRAY, GL
    RUTTIMANN, UE
    POLLACK, MM
    [J]. CRITICAL CARE MEDICINE, 1994, 22 (05) : 821 - 826
  • [6] ACCELERATED ERYTHROPOIESIS - THE HIDDEN BENEFIT OF AUTOLOGOUS DONATION
    LEVINE, E
    ROSEN, A
    SEHGAL, L
    GOULD, S
    SEHGAL, H
    MOSS, G
    [J]. TRANSFUSION, 1990, 30 (04) : 295 - 297
  • [7] ERYTHROPOIETIN DEFICIENCY AFTER CORONARY-ARTERY BYPASS PROCEDURES
    LEVINE, EA
    ROSEN, AL
    SEHGAL, LR
    GOULD, SA
    EGRIE, JC
    MOSS, GS
    [J]. ANNALS OF THORACIC SURGERY, 1991, 51 (05) : 764 - 766
  • [8] MARTIFLICH J, 1992, REAN URG, V1, P1024
  • [9] A CLINICAL-EVALUATION OF A BLOOD CONSERVATION DEVICE IN MEDICAL INTENSIVE-CARE UNIT PATIENTS
    PERUZZI, WT
    PARKER, MA
    LICHTENTHAL, PR
    COCHRANZULL, C
    TOTH, B
    BLAKE, M
    [J]. CRITICAL CARE MEDICINE, 1993, 21 (04) : 501 - 506
  • [10] EVALUATION OF A NEW BLOOD-CONSERVING ARTERIAL LINE SYSTEM FOR PATIENTS IN INTENSIVE-CARE UNITS
    SILVER, MJ
    JUBRAN, H
    STEIN, S
    MCSWEENEY, T
    JUBRAN, F
    [J]. CRITICAL CARE MEDICINE, 1993, 21 (04) : 507 - 511