Building integration of PCM for natural cooling of buildings

被引:112
作者
Alvarez, Servando [1 ]
Cabeza, Luisa F. [2 ]
Ruiz-Pardo, Alvaro [1 ]
Castell, Albert [2 ]
Tenorio, Jose Antonio [3 ]
机构
[1] Univ Seville, Escuela Ingenieros, Grp Termotecnia, Seville 41092, Spain
[2] Univ Lleida, Edifici CREA, GREA Innovacio Concurrent, Lleida 25001, Spain
[3] CSIC, Inst Eduardo Torroja, Madrid 28030, Spain
关键词
Natural cooling of buildings; Integration of PCM in buildings; Extended surfaces of heat transfer; MEDITERRANEAN CLIMATES; VENTILATED FACADES; NUMERICAL-ANALYSIS; THERMAL-BEHAVIOR; MODEL; PERFORMANCE; VALIDATION; STORAGE;
D O I
10.1016/j.apenergy.2013.01.080
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
080707 [能源环境工程]; 082001 [油气井工程];
摘要
The use of night cooling ventilation in addition of phase change materials (PCMs) is a very powerful strategy for reducing the cooling demand of buildings. Nevertheless, there are inherent drawbacks in the way things have been doing so far: (a) The limited area of contact between PCM and the air; (b) the very low convective heat transfer coefficients which prevents the use of significant amounts of PCM and (c) the very low utilization factor of the cool stored due to the large phase shift between the time when cool is stored and time when it is required by the building. In this paper, we present innovative solutions using PCM to overcome the above situation. Compared with existing solutions, innovative solutions proposed, increase the contact area between PCM and air by a factor of approximately 3.6, increase the convective heat transfer coefficient significantly, and improve the utilization factor due to the inclusion of active control systems which allow the cold stored be actually used when required. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:514 / 522
页数:9
相关论文
共 25 条
[1]
Albert Castell, 2009, ANAL IMPLEMENTATION
[2]
ALLARD F., 1998, Natural ventilation in buildings: a design handbook
[3]
Alvarez S., International Journal of Solar Energy, V19, P179, DOI [https://doi.org/10.1080/01425919708914336, DOI 10.1080/01425919708914336]
[4]
[Anonymous], 2001, 1402001 ASHRAE
[5]
[Anonymous], 13791 ENISO
[6]
[Anonymous], 12 INT C EN STOR INN
[7]
Bajare D, 2011, ENV TECHNOL RESOUR
[8]
[9]
Barnard N, 2002, INT J VENT, V1, P81
[10]
Assessment of building cooling energy need through a quasi-steady state model: Simplified correlation for gain-loss mismatch [J].
Corrado, Vincenzo ;
Fabrizio, Enrico .
ENERGY AND BUILDINGS, 2007, 39 (05) :569-579