Redox cationic or procationic labeled drugs detected at a perfluorosulfonated ionomer film-coated electrode

被引:25
作者
Limoges, B
Degrand, C
Brossier, P
机构
[1] UNIV CLERMONT FERRAND,URA 434,F-63177 CLERMONT FERRAND,FRANCE
[2] UNIV BOURGOGNE,FAC PHARM,UNITE IMMUNOANALYSE,F-21033 DIJON,FRANCE
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1996年 / 402卷 / 1-2期
关键词
redox; cations; labelled drugs; imunoassay;
D O I
10.1016/0022-0728(95)04182-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With the aim of developing a new type of immunoassay with electrochemical detection, a Nafion(R) film-modified electrode was used as an amplifying sensor to detect redox cationic labeled drugs by square-wave voltammetry, A series of amino drugs was labeled with three model redox labels, i.e. cationic cobaltocenium and procationic ferrocene and nitroxide groups. Several parameters were involved in the optimization of the analytical properties of the sensor, i.e. film processing and film thickness, accumulation time, ionic strength and ethanol content. The preconcentration of the labeled drugs was impeded by the competitive accumulation of hydrophobic amines. The accumulation process of the procationic labeled drugs was influenced significantly by the potential applied during accumulation, and their strong non-specific binding with proteins was observed in the presence of serum. Therefore the choice of cobaltocenium as a label was preferred. Optimized conditions were defined, which took into account these various aspects. The avidin-biotin system was proposed as an applicable extension of this approach.
引用
收藏
页码:175 / 187
页数:13
相关论文
共 55 条
[1]   ION ASSOCIATION AND ELECTRIC-FIELD EFFECTS ON ELECTRON HOPPING IN REDOX POLYMERS - APPLICATION TO THE OS(BPY)3(3+)/2+ COUPLE IN NAFION [J].
ANSON, FC ;
BLAUCH, DN ;
SAVEANT, JM ;
SHU, CF .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (06) :1922-1932
[2]  
BINDER P, 1990, IMMUNOANAL BIOL SPEC, V19, P23
[3]   PULSED AMPEROMETRIC DETECTION OF GLUCOSE IN BIOLOGICAL-FLUIDS AT A SURFACE-MODIFIED GOLD ELECTRODE [J].
BINDRA, DS ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1989, 61 (22) :2566-2570
[4]   IMPROVEMENT OF THE ADHESION OF A NAFION(R) MODIFYING LAYER ON ELECTRODES [J].
CHA, CS ;
CHEN, J ;
LIU, PF .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 345 (1-2) :463-467
[5]   THE DEVELOPMENT OF REDOX-MODIFIED ELECTRODES AS CHARGE-ACCUMULATING DEVICES FOR USE IN HIGHER SENSITIVITY DETECTION SYSTEMS [J].
CHAMBERS, JA ;
WALTON, NJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 250 (02) :417-425
[6]  
CHEAUVEAU J, 1991, CLIN CHEM, V37, P1178
[7]   METHYLENE-BLUE PERFLUOROSULFONATED IONOMER MODIFIED MICROCYLINDER CARBON-FIBER ELECTRODE AND ITS APPLICATION FOR THE DETERMINATION OF HEMOGLOBIN [J].
CHEN, HY ;
JU, HX ;
XUN, YG .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4538-4542
[8]   SYNTHESIS OF NITROXIDES FOR USE AS PROCATIONIC LABELS AND THEIR INCORPORATION INTO NAFION FILMS [J].
DEGRAND, C ;
LIMOGES, B ;
BLANKESPOOR, RL .
JOURNAL OF ORGANIC CHEMISTRY, 1993, 58 (09) :2573-2577
[9]   SYNTHESIS OF COBALTOCENIUM SALTS FOR USE AS REDOX LABELS AND THEIR INCORPORATION INTO NAFION FILMS [J].
DEGRAND, C ;
LIMOGES, B ;
GAUTIER, A ;
BLANKESPOOR, RL .
APPLIED ORGANOMETALLIC CHEMISTRY, 1993, 7 (04) :233-241
[10]  
DEGRAND C, 1992, Patent No. 9207089