Quantification of uncertainties in doses from intakes of radionuclides is important in risk assessments and epidemiologic studies of individuals exposed to radiation. In this study, the uncertainties in the doses per unit intake (i.e., dose coefficients) for ingestion of I-131, Cs-137, and Sr-90 by healthy individuals have been determined. Age-dependent thyroid dose coefficients were derived for I-131. The analysis for I-131 uses recent measurements of thyroid volume obtained by ultrasonography, which indicate a thyroid mass lower than that previously obtained using autopsy measurements. The coefficients for Cs-137 are determined using the relationship between the biological half-lives and the amount of potassium in the human body. The most recent International Commission on Radiological Protection biokinetic model was employed to determine the uncertainties for Sr-90. For Cs-137 and Sr-90, the dose coefficients represent exposure in adulthood and they were determined for all organs of radiological importance. The uncertainty in the estimated dose coefficients represent state of knowledge estimates for a reference individual, and they are described by lognormal distributions with a specified geometric mean (GM) and geometric standard deviation (GSD). The estimated geometric means vary only slightly from the dose coefficients reported by ICRP publications. The largest uncertainty is observed in the dose coefficients for bone surface (GSD = 2.6), and red bone marrow (GSD = 2.4) in the case of ingestion of Sr-90. For most other organs, the uncertainty in the Sr-90 dose coefficients is characterized by a GSD of 1.8 (or less for some organs). For I-131, the uncertainty in the thyroid dose coefficients is well represented by a GSD of 1.7 for both sexes and all ages other than infants for whom a GSD of 1.8 is more appropriate. The lowest uncertainties are obtained for the dose coefficients from ingestion of Cs-137 (GSD = 1.24 for males; 1.4 for females). A dominant source of uncertainty in the ingestion dose coefficients is the variation of the biokinetic parameters. For I-131, the largest contribution to the uncertainty comes from the variation in the thyroid mass, but the contribution of the biokinetic parameters is comparable. The biokinetic parameters with the largest contribution to the uncertainty are (a) the fractional uptake from blood to thyroid in the case of ingestion of I-131, (b) the absorbed fraction from the gastrointestinal tract (f(I)) in the case of Sr-90, and (c) the amount of potassium in the body for Cs-137. The contribution to the uncertainty of the absorbed fraction (which accounts for the fraction of energy deposited in the target organ) is the smallest contributor to the uncertainty in the dose coefficients for most organs. To reduce the uncertainty in the dose estimated for a real individual, one should determine the above-mentioned parameters for the specified individual rather than to rely on assumptions for a reference individual.
引用
收藏
页码:460 / 482
页数:23
相关论文
共 73 条
[2]   AVERAGE POTASSIUM CONCENTRATION OF THE HUMAN BODY AS A FUNCTION OF AGE [J].
ANDERSON, EC ;
LANGHAM, WH .
SCIENCE, 1959, 130 (3377) :713-714
[3]  
[Anonymous], 1990, GUIDE DEALING UNCERT
[4]  
[Anonymous], 1993, ANN ICRP
[5]  
Apostoaei A. I., 1998, Health Physics, V74, pS14
[6]   Absorption of strontium from the gastrointestinal tract into plasma in healthy human adults [J].
Apostoaei, AI .
HEALTH PHYSICS, 2002, 83 (01) :56-65
[7]  
APOSTOAEI AI, 1999, RADIONUCLIDES RELEAS, V4
[8]  
APOSTOAEI AI, 1999, IODINE 131 RELEASES, V1
[9]  
APOSTOAEI AI, 2001, THESIS U TENNESSEE
[10]  
AVERICHEV AA, 1994, 1994 CHERNOBYL SASAK, P51