Performance evaluation of discharge plasma process for gaseous pollutant removal

被引:144
作者
Kim, HH
Prieto, G
Takashima, K
Katsura, S
Mizuno, A
机构
[1] Toyohashi Univ Technol, Dept Ecol Engn, Toyohashi, Aichi 4418580, Japan
[2] Univ Nacl Tucuman, Dept Chem Engn, RA-4000 San Miguel De Tucuman, Tucuman, Argentina
关键词
non-thermal plasma; pulse corona discharge; scaling rule; energy constant; nitric oxide;
D O I
10.1016/S0304-3886(01)00182-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Performance evaluation of non-thermal plasma (NTP) process has been carried out using NO as a model gas. The experimental results were evaluated using a simple model, which relates the change of NO concentration with specific input energy (SIE) (kJ/Nm(3)). The results were also evaluated using the well-known parameters of energy cost, energy yield (EY) and G-value. As the SIE increased, the EY and the G-value decreased while the energy cost increased even under a given reaction condition. Based on these parameters best results were found in the smaller SIE region where the NO removal is poor. An approach has been developed to use the constant (hereafter referred to as energy constant k(E) (Nm(3)/kJ)) in a simple model to evaluate the system performance of non-thermal plasma reactor instead of conventional parameters. Unlike the three conventional parameters, the energy constant was not influenced by the SIE level under the range tested in the present work. The effects of various reaction conditions, such as initial concentration of NO, temperature, additive on the energy constant k(E) have been investigated. The comparison of k(E) values for different NO concentrations clearly showed that the NTP process is more efficient in treating gaseous pollutant in low concentration. The increase of NO concentration exponentially decreased the energy constant. Gas temperature showed a similar effect. The significance of the influence of the tested parameters on the energy constant k(E) has been found to be of the order of the gas composition, the initial concentration, and the gas temperature. Among the additives tested in this study, ethylene made the energy constant k(E) to a maximum value of 242 x 10(-3). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:25 / 41
页数:17
相关论文
共 31 条
[1]  
ALEKSEEV GY, 1993, RES REP IVTAN ANRA 9
[2]   Oxidation characteristics of nitrogen monoxide by nanosecond pulse corona discharges in a methane combustion flue gas [J].
Amirov, R. H. ;
Asinovsky, E. I. ;
Samoilov, I. S. ;
Shepelin, A. V. .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 1993, 2 (04) :289-295
[3]   CORONA DISCHARGE PROCESSES [J].
CHANG, JS ;
LAWLESS, PA ;
YAMAMOTO, T .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1991, 19 (06) :1152-1166
[4]   PULSE POWER ELECTROSTATIC TECHNOLOGIES FOR THE CONTROL OF FLUE-GAS EMISSIONS [J].
DINELLI, G ;
REA, M .
JOURNAL OF ELECTROSTATICS, 1990, 25 (01) :23-40
[5]  
HOSOKAWA S, 1996, P IEJ ESA J SYM ELEC, P41
[6]  
Kim H H., 1999, Journal of Advanced Oxidation Technology, V4, P347
[7]  
KIM JS, 1998, P ICESP VII, P249
[8]   Control of tobacco smoke and odors using discharge plasma reactor [J].
Kinoshita, K ;
Fujiyama, Y ;
Kim, HH ;
Katsura, S ;
Mizuno, A .
JOURNAL OF ELECTROSTATICS, 1997, 42 (1-2) :83-91
[9]   STREAMER DISCHARGE SIMULATION IN FLUE-GAS [J].
LI, J ;
SUN, WM ;
PASHAIE, B ;
DHALI, SK .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1995, 23 (04) :672-678
[10]   CONTROL OF NOX BY POSITIVE AND NEGATIVE PULSED CORONA DISCHARGES [J].
MASUDA, S ;
NAKAO, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (02) :374-383