Incision sizes for foldable intraocular lenses

被引:49
作者
Kohnen, T
Lambert, RJ
Koch, DD
机构
[1] BAYLOR COLL MED,CULLEN EYE INST,DEPT OPHTHALMOL,HOUSTON,TX 77030
[2] ALCON LABS INC,FT WORTH,TX 76101
关键词
D O I
10.1016/S0161-6420(97)30147-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: The purpose of the study is to determine the minimal incision sizes required for implantation of a variety of different foldable intraocular lenses (IOLs) and to evaluate the effect of incision size on tissue damage. Design: Randomized experimental study. Participants: Sixty-nine fresh human cadaveric eyes: 15 (pilot study), 48 (main study), and 6 (scanning electron microscopy study). Intervention: Implantation of foldable IOLs into cadaveric eyes. Main Outcome Measures: In 48 fresh human cadaveric eyes, limbal corneal tunnel incisions were made, and in a randomized fashion, 8 different foldable IOLs of 20.5 diopters (D) were inserted: 4 silicone (SI-30NB, Allergan Medical Optics, Irvine, CA; C10UB, Chiron Ophthalmics, Inc, Irvine, CA; L141U, IOLAB, Chiron Ophthalmics, Inc, Irvine, CA; AA-4203, Staar Surgical Company, Monrovia, CA); two soft acrylic (MA60BM and MA30BA, both Alcon Laboratories, Inc, Ft. Worth, TX); and two hydrogel models (SH30BC, Alcon; H60M, Storz Ophthalmics, Inc, St. Louis, MO). For each IOL model, six insertions were performed with a recommended implantation device. Using calipers, the authors measured internal and external incision sizes before and after insertion. Scanning electron microscopy was performed on selected incisions in six additional human cadaveric eyes. Results: Incision sizes after insertion ranged from 3.2 to 3.8 mm. The smallest incisions permitting IOL insertion were associated with the injectors. However, these incisions enlarged after insertion by approximately 11% and then were similar to the incision sizes after forceps insertion of the high-refractive-index silicone, the 5.5-mm optic acrylic, and the one-piece hydrogel IOL. The largest incisions were associated with the 6-mm acrylic IOL and the three-piece silicone IOL with a lower refractive index. The scanning electron microscopy showed tearing of corneal tissue after implantation through the smallest incision; this was more pronounced with injectors than with forceps. Conclusions: Corneal tunnel incisions enlarged up to 11% after insertion of foldable IOLs through the smallest possible incision. With current technology, the smallest postinsertion incision size of a 20.5-D foldable IOL is 3.2 mm.
引用
收藏
页码:1277 / 1286
页数:10
相关论文
共 31 条
[1]   Postoperative astigmatism and relative strength of tunnel incisions: A prospective clinical trial [J].
Anders, N ;
Pham, DT ;
Antoni, HJ ;
Wollensak, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (03) :332-336
[2]   A modified preparation technique for closed system ocular surgery of human eyes obtained postmortem - An improved research and teaching tool [J].
Auffarth, GU ;
Wesendahl, TA ;
Solomon, KD ;
Brown, SJ ;
Apple, DJ .
OPHTHALMOLOGY, 1996, 103 (06) :977-982
[3]   MULTICENTER TRIAL OF AN INTRAOCULAR HYDROGEL LENS IMPLANT [J].
BARRETT, GD ;
BEASLEY, H ;
LORENZETTI, OJ ;
ROSENTHAL, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1987, 13 (06) :621-626
[4]   KERATOMETRIC CYLINDER AND VISUAL PERFORMANCE FOLLOWING PHACOEMULSIFICATION AND IMPLANTATION WITH SILICONE SMALL-INCISION OR POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES [J].
BRINT, SF ;
OSTRICK, DM ;
BRYAN, JE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01) :32-36
[5]  
CHRIST FR, 1995, ENCY HDB BIOMATERI B, V2, P1261
[6]  
Duffey R J, 1989, Refract Corneal Surg, V5, P41
[7]   RELATIVE STABILITY OF CLEAR CORNEAL INCISIONS IN A CADAVER EYE MODEL [J].
ERNEST, PH ;
FENZL, R ;
LAVERY, KT ;
SENSOLI, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (01) :39-42
[8]   RELATIVE STRENGTH OF SCLERAL CORNEAL AND CLEAR CORNEAL INCISIONS CONSTRUCTED IN CADAVER EYES [J].
ERNEST, PH ;
LAVERY, KT ;
KIESSLING, LA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (06) :626-629
[10]   THE CORRELATION BETWEEN INCISION SIZE AND CORNEAL SHAPE CHANGES IN SUTURELESS CATARACT-SURGERY [J].
HAYASHI, K ;
HAYASHI, H ;
NAKAO, F ;
HAYASHI, F .
OPHTHALMOLOGY, 1995, 102 (04) :550-556