Validation of goose liver fat measurement by QCT and CSE-MRI with biochemical extraction and pathology as reference

被引:51
作者
Xu, Li [1 ]
Duanmu, Yangyang [1 ]
Blake, Glen M. [2 ]
Zhang, Chenxin [1 ]
Zhang, Yong [1 ]
Brown, Keenan [3 ]
Wang, Xiaoqi [4 ]
Wang, Peng [5 ]
Zhou, Xingang [5 ]
Zhang, Manling [6 ]
Wang, Chao [7 ]
Guo, Zhe [1 ]
Guglielmi, Giuseppe [8 ]
Cheng, Xiaoguang [1 ]
机构
[1] Beijing Jishuitan Hosp, Dept Radiol, 31 Xinjiekou East St, Beijing 100035, Peoples R China
[2] Kings Coll London, Dept Biomed Engn, London, England
[3] Mindways Software, Austin, TX USA
[4] Philips Healthcare, Beijing, Peoples R China
[5] Capital Med Univ, Dept Pathol, Affiliated Beijing Ditan Hosp, Beijing, Peoples R China
[6] China Natl Food & Safety Supervis & Inspect Ctr, Beijing, Peoples R China
[7] Beijing Jishuitan Hosp, Dept Stat, Beijing, Peoples R China
[8] Sci Inst Hosp, Dept Radiol, San Giovanni Rotondo, Italy
基金
中国国家自然科学基金;
关键词
Hepatic steatosis; Quantitative computed tomography; Chemical shift encoded magnetic resonance imaging; Proton density fat fraction; Hepatic triglyceride analysis; HEPATIC STEATOSIS; MAGNETIC-RESONANCE; COMPUTED-TOMOGRAPHY; NONALCOHOLIC STEATOHEPATITIS; SAMPLING VARIABILITY; MODIFIED DIXON; ECHO TIMES; DISEASE; QUANTIFICATION; ACCURACY;
D O I
10.1007/s00330-017-5189-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
This study aimed to validate the accuracy and reliability of quantitative computed tomography (QCT) and chemical shift encoded magnetic resonance imaging (CSE-MRI) to assess hepatic steatosis. Twenty-two geese with a wide range of hepatic steatosis were collected. After QCT and CSE-MRI examinations, the liver of each goose was removed and samples were taken from the left lobe, upper and lower half of the right lobe for biochemical measurement and histology. Fat percentages by QCT and proton density fat fraction by MRI (MRI-PDFF) were measured within the sample regions of biochemical measurement and histology. The accuracy of QCT and MR measurements were assessed through Spearman correlation coefficients (r) and Passing and Bablok regression equations using biochemical measurement as the "gold standard". Both QCT and MRI correlated highly with chemical extraction [r = 0.922 (p < 0.001) and r = 0.949 (p < 0.001) respectively]. Chemically extracted triglyceride was accurately predicted by both QCT liver fat percentages (Y = 0.6 + 0.866 x X) and by MRI-PDFF (Y = -1.8 + 0.773 x X). QCT and CSE-MRI measurements of goose liver fat were accurate and reliable compared with biochemical measurement. aEuro cent QCT and CSE-MRI can measure liver fat content accurately and reliably aEuro cent Histological grading of hepatic steatosis has larger sampling variability aEuro cent QCT and CSE-MRI have potential in the clinical setting.
引用
收藏
页码:2003 / 2012
页数:10
相关论文
共 48 条
[1]
[Anonymous], 2005, HUMAN BODY COMPOSITI
[2]
Quantification of Hepatic Steatosis With Dual-Energy Computed Tomography Comparison With Tissue Reference Standards and Quantitative Magnetic Resonance Imaging in the ob/ob Mouse [J].
Artz, Nathan S. ;
Hines, Catherine D. G. ;
Brunner, Stephen T. ;
Agni, Rashmi M. ;
Kuehn, Jens-Peter ;
Roldan-Alzate, Alejandro ;
Chen, Guang-Hong ;
Reeder, Scott B. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (10) :603-610
[3]
Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease [J].
Banerjee, Rajarshi ;
Pavlides, Michael ;
Tunnicliffe, Elizabeth M. ;
Piechnik, Stefan K. ;
Sarania, Nikita ;
Philips, Rachel ;
Collier, Jane D. ;
Booth, Jonathan C. ;
Schneider, Jurgen E. ;
Wang, Lai Mun ;
Delaney, David W. ;
Fleming, Ken A. ;
Robson, Matthew D. ;
Barnes, Eleanor ;
Neubauer, Stefan .
JOURNAL OF HEPATOLOGY, 2014, 60 (01) :69-77
[4]
Quantitative magnetic resonance imaging of hepatic steatosis: Validation in ex vivo human livers [J].
Bannas, Peter ;
Kramer, Harald ;
Hernando, Diego ;
Agni, Rashmi ;
Cunningham, Ashley M. ;
Mandal, Rakesh ;
Motosugi, Utaroh ;
Sharma, Samir D. ;
del Rio, Alejandro Munoz ;
Fernandez, Luis ;
Reeder, Scott B. .
HEPATOLOGY, 2015, 62 (05) :1444-1455
[5]
Prevalence of and risk factors for nonalcoholic fatty liver disease: The Dionysos Nutrition and Liver Study [J].
Bedogni, G ;
Miglioli, L ;
Masutti, F ;
Tiribelli, C ;
Marchesini, G ;
Bellentani, S .
HEPATOLOGY, 2005, 42 (01) :44-52
[6]
Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[7]
Two-point Dixon Method With Flexible Echo Times [J].
Berglund, Johan ;
Ahlstroem, Hakan ;
Johansson, Lars ;
Kullberg, Joel .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) :994-1004
[8]
The diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis compared with liver biopsy: a meta-analysis [J].
Bohte, Anneloes E. ;
van Werven, Jochem R. ;
Bipat, Shandra ;
Stoker, Jaap .
EUROPEAN RADIOLOGY, 2011, 21 (01) :87-97
[9]
Brunt EM, 1999, AM J GASTROENTEROL, V94, P2467, DOI 10.1111/j.1572-0241.1999.01377.x
[10]
PRECISE MEASUREMENT OF VERTEBRAL MINERAL-CONTENT USING COMPUTED-TOMOGRAPHY [J].
CANN, CE ;
GENANT, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) :493-500