Cyclodextrin-based optosensor for the determination of warfarin in waters

被引:25
作者
Badía, R [1 ]
Díaz-García, ME [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, Oviedo, Spain
关键词
optosensor; flow injection analysis (FIA); cyclodextrin; warfarin;
D O I
10.1021/jf981330u
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A flow-through optosensor for warfarin is described. The sensor is developed in conjunction with flow analysis systems and uses a commercial bound beta-cyclodextrin material as the sensing phase. A strong fluorescence signal was observed as a result of the formation of an inclusion complex between warfarin and beta-cyclodextrin, The analytical performance characteristics of the proposed sensor for analysis of low levels of warfarin were as follows: the detection limits for continuous and flow injection analysis systems were 2 and 19 ppb, respectively; the observed relative standard deviations at 0.5 ppm warfarin level were less than 2.3%. A study of the interference of other naphthalenic toxic substances was carried out. The continuous flow method was satisfactorily applied to the determination of the rodenticide in natural waters.
引用
收藏
页码:4256 / 4260
页数:5
相关论文
共 32 条
[1]   A FIBEROPTIC CYCLODEXTRIN-BASED SENSOR [J].
ALARIE, JP ;
VO-DINH, T .
TALANTA, 1991, 38 (05) :529-534
[2]  
ANDERSEN C, 1993, J CHROMATOGR-BIOMED, V126, P159
[3]   CYCLODEXTRIN BONDED PHASES FOR THE LIQUID-CHROMATOGRAPHIC SEPARATION OF OPTICAL, GEOMETRICAL, AND STRUCTURAL ISOMERS [J].
ARMSTRONG, DW ;
DEMOND, W .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (09) :411-415
[4]  
Atwood J.L., 1996, COMPREHENSIVE SUPRAM
[5]  
DELAPENA AM, 1993, J INCLUS PHENOM MOL, V15, P131
[6]   Extraction of PAHs and pesticides from contaminated soils with aqueous CD solutions [J].
Fenyvesi, E ;
Szeman, J ;
Szejtli, J .
JOURNAL OF INCLUSION PHENOMENA AND MOLECULAR RECOGNITION IN CHEMISTRY, 1996, 25 (1-3) :229-232
[7]  
GARCIA RP, 1991, ANAL CHEM, V63, P1759
[8]   SEPARATION AND DETERMINATION OF WARFARIN ENANTIOMERS IN HUMAN PLASMA SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS USING A METHYLATED BETA-CYCLODEXTRIN-CONTAINING ELECTROLYTE [J].
GAREIL, P ;
GRAMOND, JP ;
GUYON, F .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 615 (02) :317-325
[9]   Voltammetric responsive sensors for organic compounds based on organized self-assembled lipoyl-beta-cyclodextrin derivative monolayer on a gold electrode [J].
He, PA ;
Ye, JN ;
Fang, YH ;
Suzuki, I ;
Osa, T .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :217-223
[10]   CYCLODEXTRINS AND THEIR APPLICATIONS IN ANALYTICAL-CHEMISTRY [J].
LI, S ;
PURDY, WC .
CHEMICAL REVIEWS, 1992, 92 (06) :1457-1470