Detection and Localization of Myocardial Infarction using K-nearest Neighbor Classifier

被引:153
作者
Arif, Muhammad [1 ]
Malagore, Ijaz A. [2 ]
Afsar, Fayyaz A. [2 ]
机构
[1] Air Univ, Dept Comp Sci & Engn, Islamabad, Pakistan
[2] PIEAS, Dept Comp & Informat Sci, Islamabad, Pakistan
关键词
Myocardial infarction; K-nearest neighbor; ECG; Pruning;
D O I
10.1007/s10916-010-9474-3
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
This paper presents automatic detection and localization of myocardial infarction (MI) using K-nearest neighbor (KNN) classifier. Time domain features of each beat in the ECG signal such as T wave amplitude, Q wave and ST level deviation, which are indicative of MI, are extracted from 12 leads ECG. Detection of MI aims to classify normal subjects without myocardial infarction and subjects suffering from Myocardial Infarction. For further investigation, Localization of MI is done to specify the region of infarction of the heart. Total 20,160 ECG beats from PTB database available on Physio-bank is used to investigate the performance of extracted features with KNN classifier. In the case of MI detection, sensitivity and specificity of KNN is found to be 99.9% using half of the randomly selected beats as training set and rest of the beats for testing. Moreover, Arif-Fayyaz pruning algorithm is used to prune the data which will reduce the storage requirement and computational cost of search. After pruning, sensitivity and specificity are dropped to 97% and 99.6% respectively but training is reduced by 93%. Myocardial Infarction beats are divided into ten classes based on the location of the infarction along with one class of normal subjects. Sensitivity and Specificity of above 90% is achieved for all eleven classes with overall classification accuracy of 98.8%. Some of the ECG beats are misclassified but interestingly these are misclassified to those classes whose location of infarction is near to the true classes of the ECG beats. Pruning is done on the training set for eleven classes and training set is reduced by 70% and overall classification accuracy of 98.3% is achieved. The proposed method due to its simplicity and high accuracy over the PTB database can be very helpful in correct diagnosis of MI in a practical scenario.
引用
收藏
页码:279 / 289
页数:11
相关论文
共 26 条
[1]  
[Anonymous], P COMP CARD
[2]  
[Anonymous], P NAT SCI C 2007
[3]  
[Anonymous], 2 INT C BIOEL
[4]  
[Anonymous], EDITORS ADV METHODS
[5]  
[Anonymous], 2001, IEE T JPN
[6]  
[Anonymous], ASIAN J INF TECHNOL
[7]  
[Anonymous], DIGITAL SIGNAL PROCE
[8]  
[Anonymous], P 14 INT C SYST SIGN
[9]  
[Anonymous], P COMP CARD
[10]  
[Anonymous], IEEE T PATTERN ANAL