Modeling of 5′ nuclease real-time responses for optimization of a high-throughput enrichment PCR procedure for Salmonella enterica

被引:51
作者
Knutsson, R
Löfström, C
Grage, H
Hoorfar, J
Rådstrom, P
机构
[1] Lund Univ, Lund Inst Technol, Ctr Chem & Chem Engn, SE-22100 Lund, Sweden
[2] Lund Univ, Dept Math Stat, Lund, Sweden
[3] Danish Vet Lab, Copenhagen, Denmark
关键词
D O I
10.1128/JCM.40.1.52-60.2002
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The performance of a 5' nuclease real-time PCR assay was studied to optimize an automated method of detection of preenriched Salmonella enterica cells in buffered peptone water (BPW). The concentrations and interactions of the PCR reagents were evaluated on the basis of two detection responses, the threshold cycle (C-T) and the fluorescence intensity by a normalized reporter value (DeltaR(n)). The C-r response was identified as the most suitable for detection modeling to describe the PCR performances of different samples. DNA extracted from S. enterica serovar Enteritidis was studied in double-distilled H2O (ddH(2)O) and in two different enrichment media (brain heart infusion and BPW) with two PCR mixtures based on AmpliTaq Gold or rTth. A descriptive model was proposed and fitted to the available experimental data. Equivalent PCR performances for the two PCR mixtures were obtained when DNA was diluted in ddH(2)O. However, the level of detection of DNA was affected when BPW was present during amplification. Use of the rTth mixture generated a 1-log-unit wider linear range of amplification, and the DNA detection levels were 2 x 10(-13) g/microwell for the rTth mixture and 2 x 10(-12) g/microwell for the AmpliTaq Gold mixture. To verify the improved amplification capacity of the rTth mixture, BPW was inoculated with 1 CFU of S. enterica serovar Enteritidis per ml and the mixture was incubated at 30degreesC. Samples for PCR were withdrawn every 4 h during a 36-h enrichment. Use of the rTth mixture resulted in an earlier PCR detection during enrichment than use of the AmpliTaq Gold mixture. For accurate detection (C-T less than or equal to 30) of S. enterica serovar Enteritidis inoculated in BPW, the rTth mixture required 8.4 h of enrichment, while the AmpliTaq Gold mixture needed 11.6 h. In conclusion, the principle applied can improve the methodology of 5' nuclease real-time PCR for numerical optimization of sample pretreatment strategies to provide automated diagnostic PCR procedures.
引用
收藏
页码:52 / 60
页数:9
相关论文
共 38 条
[1]   Effects of amplification facilitators on diagnostic PCR in the presence of blood, feces, and meat [J].
Abu Al-Soud, W ;
Rådström, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (12) :4463-4470
[2]   Purification and characterization of PCR-inhibitory components in blood cells [J].
Abu al-Soud, W ;
Rådström, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) :485-493
[3]  
Abu Al-Soud W, 1998, APPL ENVIRON MICROB, V64, P3748
[4]  
AGRESTI A., 2019, INTRO CATEGORICAL DA
[5]   USE OF A FLUOROGENIC PROBE IN A PCR-BASED ASSAY FOR THE DETECTION OF LISTERIA-MONOCYTOGENES [J].
BASSLER, HA ;
FLOOD, SJA ;
LIVAK, KJ ;
MARMARO, J ;
KNORR, R ;
BATT, CA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (10) :3724-3728
[6]   Molecular diagnostics for dairy-borne pathogens [J].
Batt, CA .
JOURNAL OF DAIRY SCIENCE, 1997, 80 (01) :220-229
[7]   The evaluation of a fluorogenic polymerase chain reaction assay for the detection of Salmonella species in food commodities [J].
Chen, S ;
Yee, A ;
Griffiths, M ;
Larkin, C ;
Yamashiro, CT ;
Behari, R ;
PaszkoKolva, C ;
Rahn, K ;
DeGrandis, SA .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1997, 35 (03) :239-250
[8]  
Favre N, 1996, BIOTECHNIQUES, V21, P28
[9]  
*FDA, 1998, BACT AN MAN
[10]   Quantitative RT-PCR: Pitfalls and potential [J].
Freeman, WM ;
Walker, SJ ;
Vrana, KE .
BIOTECHNIQUES, 1999, 26 (01) :112-+