Emission of ammonia from indoor concrete wall and assessment of human exposure

被引:74
作者
Bai, Z
Dong, Y
Wang, Z
Zhu, T
机构
[1] Nankai Univ, Coll Environm Sci & Engn, State Environm Protect Key lab Urban Ambient Air, Tianjin 300071, Peoples R China
[2] Tianjin Polytech Univ, Inst Mat Sci & Chem Engn, Tianjin 300160, Peoples R China
关键词
ammonia; concrete; emission; chamber; exposure; potential dose;
D O I
10.1016/j.envint.2005.06.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Addition of urea-based antifreeze admixtures during cement mixing can make it possible to produce concrete cement in construction of buildings in cold weather; this, however, has led to increasing indoor air pollution due to continuous transformation and emission from urea to gaseous ammonia in indoor concrete wall. It is believed that ammonia is harmful to human body and exposure to ammonia can cause some serious symptoms such as headaches, hunts, and even permanent damage to the eyes and lungs. In order to understand the emission of ammonia from indoor concrete wall in civil building and assess the health fisk of people living in these buildings, the experimental pieces of concrete wall were first prepared by concreting cement and urea-based antifreeze admixtures to simulate the indoor wall in civil building in this work. Then environmental chamber was adopted for studying the effect of temperature, relative humility and air exchange rate on emission of ammonia from experimental pieces of concrete wall. Also the field experiment was made at selected rooms in given civil buildings. Exposure and potential dose of adult and children exposed to indoor/outdoor ammonia in summer and in winter are calculated and evaluated by using Scenario Evaluation Approach. The results indicated that high air exchange rate leads to decreased ammonia concentration, and elevation of temperature causes increasing ammonia concentration and volatilizing rate in chamber. The complete emission of ammonia from the wall containing urea-based antifreeze admixtures needs more than 10 years in general. Ventilating or improving air exchange can play a significant role in reducing ammonia concentration in actual rooms in field experiments. Urea-based antifreeze admixtures in concrete wall can give rise to high exposure and potential dose, especially in summer. Generally, adults have a high potential dose than children, while children have personal average dose rate beyond adults in the same conditions. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:303 / 311
页数:9
相关论文
共 17 条
[1]   Anhydrous ammonia burns case report and review of the literature [J].
Amshel, CE ;
Fealk, MH ;
Phillips, BJ ;
Caruso, DM .
BURNS, 2000, 26 (05) :493-497
[2]  
[Anonymous], 2002, P INDOOR AIR, DOI DOI 10.3130/JAABE.2.55
[3]  
BAI Z, 2001, P 2 AS S RISK ASS MA, P204
[4]  
*ENG TOOLB, AMM NH3 CONC AIR HLT
[5]  
*FINN SOC IND AIR, 2000, PUBL FINN SOC IND AI, V5, P40
[6]   Automated measurements of ammonia and nitric acid in indoor and outdoor air [J].
Fischer, ML ;
Littlejohn, D ;
Lunden, MM ;
Brown, NJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (10) :2114-2119
[7]  
Li Y, 1994, 2 IND AIR QUAL AS IN, P262
[8]  
Liang B., 2001, P INT WORKSH IND AIR, P86
[9]  
Puhakka E, 1996, 6 HLTH BUILD INT C M, V3, P451
[10]   INDOOR OUTDOOR RELATIONSHIP OF AMMONIA CONCENTRATIONS IN SELECTED OFFICE BUILDINGS [J].
SISOVIC, A ;
SEGA, K ;
KALINIC, N .
SCIENCE OF THE TOTAL ENVIRONMENT, 1987, 61 :73-77