In vitro corrosion testing of PVD coatings applied to a surgical grade Co-Cr-Mo alloy

被引:27
作者
Bolton, J [1 ]
Hu, X [1 ]
机构
[1] Univ Bradford, Dept Mech & Med Engn, Bradford BD7 1DP, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1023/A:1015126810485
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Toxic effects and biological reaction of metallic corrosion and wear products are an important concern for metal on metal artificial joints. Corrosion tests were conducted to study the susceptibility to pitting and localized corrosion, with three coatings, CrN, TiN and DLC, applied to a wrought high carbon Co-Cr-Mo alloy substrate material. Corrosion testing involved the measurement of potential time transients during immersion in a physiological solution and cyclic polarization of specimen potentials into the transpassive range followed by reversal of the potential to scan in the cathodic direction to regain the rest potential E-rest. Resistance to pitting and localized corrosion was assessed by determining the transpassive breakdown potential E-bd and if any hysteresis generated during the reverse cyclic scan may have caused crossover with the original anodic scan. Three different surface coating conditions were tested namely: (1) as-coated, (2) polished, and (3) indented to penetrate the coating by diamond pyramid hardness indentor. Results showed that all three coatings produced significant improvements in corrosion resistance compared to performance of the wrought cobalt alloy but that some corrosive attack to both the CrN and TiN coatings occurred and some risk of attack to the cobalt alloy substrate existed due to coating defects or when damage to the coating occurred. TiN coatings were highly effective in preventing corrosion provided they were thick enough to produce complete coverage. Thin TiN coatings displayed some tendency to encourage localized attack of the cobalt alloy at coating defects or where the coating suffered mechanical damage. CrN coatings underwent transpassive breakdown more easily and some degree of pitting at defects within the coating was observed, especially when the CrN coating was polished before the test. No corrosive attack of the cobalt alloy substrate was observed when the CrN coating was mechanically damaged by indentation. DLC coatings produced were much thinner than either of the other two coatings and proved to be rather fragile. They were less effective in preventing apparently high corrosion currents and possibly high rates of corrosion. (C) 2002 Kluwer Academic Publishers.
引用
收藏
页码:567 / 574
页数:8
相关论文
共 24 条
[1]  
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[2]  
[Anonymous], 1993, TECH ORTHOP
[3]   RESORPTION OF BONE BY INFLAMMATORY CELLS DERIVED FROM THE JOINT CAPSULE OF HIP ARTHROPLASTIES [J].
ATHANASOU, NA ;
QUINN, J ;
BULSTRODE, CJK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :57-62
[4]  
BECKER BS, 1996, THESIS U BRADFORD UK
[5]   A study of the corrosion behaviour and protective quality of sputtered chromium nitride coatings [J].
Bertrand, G ;
Mahdjoub, H ;
Meunier, C .
SURFACE & COATINGS TECHNOLOGY, 2000, 126 (2-3) :199-209
[6]  
Chan FW, 1996, CLIN ORTHOP RELAT R, P96
[7]   THE EFFECT OF BIOLOGICAL-FLUIDS ON THE ADHESION OF DIAMOND-LIKE CARBON-FILMS TO METALLIC SUBSTRATES [J].
CHANDRA, L ;
ALLEN, M ;
BUTTER, R ;
RUSHTON, N ;
LETTINGTON, AH ;
CLYNE, TW .
DIAMOND AND RELATED MATERIALS, 1995, 4 (5-6) :852-856
[8]   CONCENTRATION OF WEAR PRODUCTS IN HAIR, BLOOD, AND URINE AFTER TOTAL HIP REPLACEMENT [J].
COLEMAN, RF ;
HERRINGTON, J ;
SCALES, JT .
BMJ-BRITISH MEDICAL JOURNAL, 1973, 1 (5852) :527-529
[9]  
Cooper R A, 1992, J Arthroplasty, V7, P285, DOI 10.1016/0883-5403(92)90050-Z
[10]  
Doorn PF, 1998, J BIOMED MATER RES, V42, P103, DOI 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.3.CO