Pulsed amperometric detection of underivatized amino acids using polypyrrole modified copper electrode in acidic solution

被引:10
作者
Deore, BA [1 ]
Shiigi, H [1 ]
Nagaoka, T [1 ]
机构
[1] Yamaguchi Univ, Dept Appl Chem, Fac Engn, Ube, Yamaguchi 7558611, Japan
关键词
amino acids; polypyrrole; electrocatalytic properties;
D O I
10.1016/S0039-9140(02)00204-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The successful pulsed amperometric detection of underivatized amino acids have been carried out in an acidic media on a polypyrrole (PPy) modified Cu electrode. The formation of PPy film doped with glutamate (glu) on a Cu electrode surface changes the mechanism of Cu dissolution. After application of multistep potential waveform, the PPy film was glu free due to the electro-reduction and overoxidation. High anodic potential polarization treatment yielded partially overoxidized PPy film as long as the Cu surface dissolution and amino acid permeation through the film was well controlled. This overoxidized PPy film acted as a charge and size exclusion barrier in order to improve the selectivity and stability of a Cu electrode. Various process parameters such as film modification time, detection and cleaning potential and pH of solution have been optimized to maximize the beneficial electrocatalytic properties of the electrode surface. At an optimized condition, detection limits for positively charged histidine and arginine are 19 and 22 pg respectively, whereas the neutral amino acids detected in amounts of 0.9-2.3 ng. Furthermore, the PPy coated Cu electrode response was long lived, stable and reproducible. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1203 / 1211
页数:9
相关论文
共 33 条
[1]   THE SEPARATION OF 24 OPA-AA OF NATURAL ORIGIN AND QUANTITATIVE-ANALYSIS OF TYROSINE BY MEANS OF HPLC [J].
ABECASSIS, J ;
DAVIDETEVE, C ;
SOUN, A .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (01) :135-153
[2]  
Adams R.N., 1969, Electrochemistry at Solid Electrodes
[3]  
Ahuja S., 1989, Selectivity and Detectability Optimization in HPLC
[4]  
[Anonymous], **DROPPED REF**
[5]   ELECTROCATALYSIS AT PLATINUM-ELECTRODES FOR ANODIC ELECTROANALYSIS [J].
AUSTIN, DS ;
POLTA, JA ;
POLTA, TZ ;
TANG, APC ;
CABELKA, TD ;
JOHNSON, DC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 168 (1-2) :227-248
[6]   PULSED AMPEROMETRIC DETECTION BASED ON DIRECT AND INDIRECT ANODIC REACTIONS - A REVIEW [J].
AUSTINHARRISON, DS ;
JOHNSON, DC .
ELECTROANALYSIS, 1989, 1 (03) :189-197
[7]   ORGANIC ELECTROCHEMISTRY IN THE SOLID STATE-OVEROXIDATION OF POLYPYRROLE [J].
BECK, F ;
BRAUN, P ;
OBERST, M .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1987, 91 (09) :967-974
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - PAST DEVELOPMENTS, PRESENT STATUS, AND FUTURE-TRENDS [J].
BROWN, PR .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :A995-&
[9]   POLYMER-FILMS ON ELECTRODES .7. ELECTROCHEMICAL-BEHAVIOR AT POLYPYRROLE-COATED PLATINUM AND TANTALUM ELECTRODES [J].
BULL, RA ;
FAN, FRF ;
BARD, AJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (05) :1009-1015
[10]   COPPER(2) CHELATES OF HISTIDYLHISTIDINE + RELATED COMPOUNDS [J].
DORAN, MA ;
CHABEREK, S ;
MARTELL, AE .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1964, 86 (11) :2129-&