Optical colorimetric sensor strip for direct readout glucose measurement

被引:60
作者
Wang, Xu-dong [1 ]
Chen, Hai-xu [1 ]
Zhou, Ting-yao [1 ]
Lin, Zhi-jie [1 ]
Zeng, Jing-bin [1 ]
Xie, Zhao-xiong [3 ,4 ]
Chen, Xi [1 ,2 ]
Wong, Kwok-yin [5 ]
Chen, Guo-nan [6 ,7 ]
Wang, Xiao-ru [1 ]
机构
[1] Xiamen Univ, Key Lab Analyt Sci, Minist Educ, Coll Chem & Chem Engn, Xiamen 361005, Peoples R China
[2] Xiamen Univ, State Key Lab Marine Environm Sci, Xiamen 361005, Peoples R China
[3] Xiamen Univ, State Key Lab Phys Chem Solid Surface, Xiamen 361005, Peoples R China
[4] Xiamen Univ, Dept Chem, Xiamen 361005, Peoples R China
[5] Hong Kong Polytech Univ, Dept Appl Biol & Chem Technol, Kowloon, Hong Kong, Peoples R China
[6] Fuzhou Univ, MOE Key Lab Anal & Detect Technol Food Safety, Fuzhou 350002, Fujian, Peoples R China
[7] Fuzhou Univ, Dept Chem, Fuzhou 350002, Fujian, Peoples R China
关键词
Direct readout; Calorimetric; Glucose sensor strip; High resolution; Extended detection range; FIBEROPTIC CHEMICAL SENSORS; BIOSENSORS; GEL;
D O I
10.1016/j.bios.2009.05.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel direct readout colorimetric optical glucose sensor strip was constructed based on a three-layer film, including a green-emitted CdTe/CdS quantum dots (QDs) layer as a stable color background, a red-fluorescent platinum-porphyrin oxygen-sensing layer and a glucose oxidase layer. The sensor achieved high resolution (up to 0.2 mmol L-1) glucose determination with a detection range from 0 to 3.0 mmol L-1. A "glucose ruler" which acts as a glucose standard colorimetric card was obtained. Glucose concentration could easily be directly readout using the "glucose ruler", which made the glucose determination rapid, convenient and easy. The effects of pH, salinity and temperature were systematically investigated. The prepared sensor was finally applied for glucose sample analysis, compared with the "glucose ruler", accurate results could be directly readout. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3702 / 3705
页数:4
相关论文
共 34 条
[31]   Sol-gel based glucose biosensors employing optical oxygen transducers, and a method for compensating for variable oxygen background [J].
Wolfbeis, OS ;
Oehme, I ;
Papkovskaya, N ;
Klimant, I .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (1-2) :69-76
[32]   Fiber-optic chemical sensors and biosensors [J].
Wolfbeis, Otto S. .
ANALYTICAL CHEMISTRY, 2008, 80 (12) :4269-4283
[33]   Fiber-optic chemical sensors and biosensors [J].
Wolfbeis, Otto S. .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3859-3873
[34]   A fluorescent glucose biosensor based on immobilized glucose oxidase on bamboo inner shell membrane [J].
Yang, XF ;
Zhou, ZD ;
Xiao, D ;
Choi, MMF .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1613-1620