Influence of varying compressive loading methods on physiologic motion patterns in the cervical spine

被引:30
作者
Bell, Kevin M. [1 ]
Yan, Yiguo [1 ]
Debski, Richard E. [2 ]
Sowa, Gwendolyn A. [3 ]
Kang, James D. [1 ]
Tashman, Scott [1 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Orthopaed Surg, Ferguson Lab Spine Res, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Sch Med, Dept Bioengn, Pittsburgh, PA USA
[3] Univ Pittsburgh, Sch Med, Dept Phys Med & Rehabil, Pittsburgh, PA USA
基金
美国国家卫生研究院;
关键词
Cervical spine; Kinematics; Range of motion; ROM; Follower load; Compressive preload; Hybrid control; Robotics; Bi-plane radiography; In-vivo; TOTAL DISC REPLACEMENT; FLEXION-EXTENSION; IN-VIVO; MOVEMENT; KINEMATICS; PRELOAD; 2-LEVEL; FUSION; BIOMECHANICS; DISKECTOMY;
D O I
10.1016/j.jbiomech.2015.11.045
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The human cervical spine supports substantial compressive load in-vivo arising from muscle forces and the weight of the head. However, the traditional in-vitro testing methods rarely include compressive loads, especially in investigations of multi-segment cervical spine constructs. Various methods of modeling physiologic loading have been reported in the literature including axial forces produced with inclined loading plates, eccentric axial force application, follower load, as well as attempts to individually apply/model muscle forces in-vitro. The importance of proper compressive loading to recreate the segmental motion patterns exhibited in-vivo has been highlighted in previous studies. However, appropriate methods of representing the weight of head and muscle loading are currently unknown. Therefore, a systematic comparison of standard pure moment with no compressive loading versus published and novel compressive loading techniques (follower load - FL, axial load - AL, and combined load- CL) was performed. The present study is unique in that a direct comparison to continuous cervical kinematics over the entire extension to flexion motion path was possible through an ongoing intra-institutional collaboration. The pure moment testing protocol without compression or with the application of follower load was not able to replicate the typical in-vivo segmental motion patterns throughout the entire motion path. Axial load or a combination of axial and follower load was necessary to mimic the in-vivo segmental contributions at the extremes of the extension-flexion motion path. It is hypothesized that dynamically altering the compressive loading throughout the motion path is necessary to mimic the segmental contribution patterns exhibited in-vivo. Published by Elsevier Ltd.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 36 条
[1]
Spine biomechanics [J].
Adams, MA ;
Dolan, P .
JOURNAL OF BIOMECHANICS, 2005, 38 (10) :1972-1983
[2]
Subject-Specific Inverse Dynamics of the Head and Cervical Spine During in Vivo Dynamic Flexion-Extension [J].
Anderst, William J. ;
Donaldson, William F., III ;
Lee, Joon Y. ;
Kang, James D. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (06)
[3]
Cervical Motion Segment Percent Contributions to Flexion-Extension During Continuous Functional Movement in Control Subjects and Arthrodesis Patients [J].
Anderst, William J. ;
Donaldson, William F., III ;
Lee, Joon Y. ;
Kang, James D. .
SPINE, 2013, 38 (09) :E533-E539
[4]
Cervical spine intervertebral kinematics with respect to the head are different during flexion and extension motions [J].
Anderst, William J. ;
Donaldson, William F. ;
Lee, Joon Y. ;
Kang, James D. .
JOURNAL OF BIOMECHANICS, 2013, 46 (08) :1471-1475
[5]
Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement [J].
Anderst, William J. ;
Baillargeon, Emma ;
Donaldson, William F., III ;
Lee, Joon Y. ;
Kang, James D. .
SPINE, 2011, 36 (06) :E393-E400
[6]
Bell K.M., 2007, P 53 ANN M ORTH RES
[7]
Co-contraction of cervical muscles during sagittal and coronal neck motions at different movement speeds [J].
Cheng, Chih-Hsiu ;
Lin, Kwan-Hwa ;
Wang, Jaw-Lin .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2008, 103 (06) :647-654
[8]
Biomechanical Analysis of the Range of Motion After Placement of a Two-Level Cervical ProDisc-C Versus Hybrid Construct [J].
Cho, Bo Young ;
Lim, Jesse ;
Sim, Hong Bo ;
Park, Jon .
SPINE, 2010, 35 (19) :1769-1776
[9]
Cook D.J., 2009, Characterization of the Response of the Cadaveric Human Spine to Loading in a Six-Degree-of-Freedom Spine Testing Apparatus
[10]
In vitro axial preload application during spine flexibility testing: towards reduced apparatus-related artefacts [J].
Cripton, PA ;
Bruehlmann, SB ;
Orr, TE ;
Oxland, TR ;
Nolte, LP .
JOURNAL OF BIOMECHANICS, 2000, 33 (12) :1559-1568