Assessment of pollutant emissions from dry-process photocopiers

被引:61
作者
Brown, SK [1 ]
机构
[1] CSIRO, Bldg Construct & Engn, Highett, Vic 3190, Australia
来源
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE | 1999年 / 9卷 / 04期
关键词
photocopier; VOCs; particulates; chamber measurements; emission; sink;
D O I
10.1111/j.1600-0668.1999.00005.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Processes involved in pollutant emissions from a dry-process photocopier have been investigated in a controlled room dynamic environmental chamber. Volatile organic compound (VOC) emissions occurred at a constant rate dependent on copy speed. However, VOC emission rates per copy were increased by increases in chamber temperature (e.g., a 20% increase resulted from increasing temperature from 23 degrees C to 32 degrees C) or changing from single- to double-sided operation (40% increase). Respirable particle emissions occurred under copier-idle mode (probably from residues in the machine) as well as with copying. No significant chamber sink effects were observed for VOCs or respirable particles. Small emissions of nitrogen dioxide, ozone and formaldehyde were observed but were difficult to interpret. A procedure for assessing pollutant emissions from photocopiers is recommended.
引用
收藏
页码:259 / 267
页数:9
相关论文
共 14 条
[1]  
*ASTM, 1991, D160791 ASTM
[2]  
Devos M., 1990, STANDARDIZED HUMAN O
[3]  
HETES R, 1995, EPA600R95045
[4]  
HOWARD EM, 1995, ENG SOLUTIONS INDOOR, P61
[5]  
LEOVIC KW, 1995, ENG SOLUTIONS INDOOR, P107
[6]  
MASON MA, 1997, ENG SOLUTIONS INDOOR, P45
[7]  
*NHMRC, 1992, NAT IND AIR QUAL GOA
[8]  
NORTHEIM CM, 1998, EPA600R98080
[9]  
*STAND AUSTR, 1995, AS236561995 STAND AU
[10]  
Sundell J, 1996, ASHRAE J, V38, P51