Relationship between plain radiographic patterns and three-dimensional trabecular architecture in the human calcaneus

被引:63
作者
Luo, G
Kinney, JH
Kaufman, JJ
Haupt, D
Chiabrera, A
Siffert, RS
机构
[1] Mt Sinai Sch Med, Dept Orthopaed, New York, NY 10029 USA
[2] NYU Med Ctr, Dept Rehabil Med, New York, NY 10016 USA
[3] Dept Vet Affairs Med Ctr, New York, NY USA
[4] Univ Calif Lawrence Livermore Natl Lab, Dept Mat Sci, Livermore, CA USA
[5] Univ Genoa, DIBE, I-16145 Genoa, Italy
关键词
Micro-CT; osteoporosis; plain radiograph; three-dimensional; trabecular bone; trabecular architecture;
D O I
10.1007/s001980050156
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to determine the relationship between three-dimensional (3D) trabecular structure and two-dimensional plain radiographic patterns. An in vitro cylinder of human calcaneal trabecular bone was three-dimensionally imaged by micro-CT using synchrotron radiation, at 33.4 mu m resolution. The original 3D image was processed using 14 distinct sequences of morphologic operations, i.e., of dilations and erosions, to obtain a total of 15 3D models or images of calcaneal trabecular bone. These 15 models had distinct densities (volume fractions) and architectures. The 3D structure of each calcaneal model was assessed using mean intercept length (fabric), by averaging individual fabric measurements associated with each medial-lateral image slice, and determining the relative anisotropy, R-3D, Of the structure. A summated pattern or plain radiograph was also computed from the 3D image data for each calcaneal model. Each summated pattern was then locally thresholded, and the resulting two-dimensional (2D) binary image analyzed using the same fabric analysis as used for the 3D data. The anisotropy of the 2D summated pattern was denoted by Rx-ray. The volume fractions of the 15 models ranged from 0.08 to 0.19 with a mean of 0.14. The medial-lateral anisotropies, R-3D, ranged from 1.38 to 2.54 with a mean of 1.88. The anisotropy of the 2D summated patterns, Rx-ray, ranged from 1.35 to 2.18 with a mean of 1.71. The linear correlation of the 3D trabecular architecture, R-3D, With the radiographic trabecular architecture, Rx-ray, was 0.99 (p<0.0001). This study shows that the plain radiograph contains architectural information directly related to the underlying 3D structure. A well-controlled sequential reproducible plain radiograph may prove useful for monitoring changes in trabecular architecture in vivo and in identifying those individuals at increased risk of osteoporotic fracture.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 25 条
  • [1] BENHAMOU CL, 1994, J BONE MINER RES, V9, P1909
  • [2] FRACTAL SIGNATURE ANALYSIS OF MACRORADIOGRAPHS MEASURES TRABECULAR ORGANIZATION IN LUMBAR VERTEBRAE OF POSTMENOPAUSAL WOMEN
    BUCKLANDWRIGHT, JC
    LYNCH, JA
    RYMER, J
    FOGELMAN, I
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (02) : 106 - 112
  • [3] COMPUTERIZED RADIOGRAPHIC ANALYSIS OF OSTEOPOROSIS - PRELIMINARY EVALUATION
    CALIGIURI, P
    GIGER, ML
    FAVUS, MJ
    JIA, H
    DOI, K
    DIXON, LB
    [J]. RADIOLOGY, 1993, 186 (02) : 471 - 474
  • [4] CHUNG HW, 1995, J BONE MINER RES, V10, P803
  • [5] Cortet B, 1995, REV RHUM, V62, P781
  • [6] Genant HK, 1996, J BONE MINER RES, V11, P707
  • [7] A NEW METHOD FOR AUTOMATIC RECOGNITION OF THE RADIOGRAPHIC TRABECULAR PATTERN
    GERAETS, WGM
    VANDERSTELT, PF
    NETELENBOS, CJ
    ELDERS, PJM
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1990, 5 (03) : 227 - 233
  • [8] Gonzalez RC, 1987, Digital Image Processing, V2nd
  • [9] KAUFMAN JJ, 1991, T ORTHOPAED RES SOC, V16, P429
  • [10] KAUFMAN JJ, 1987, T ORTHOPAEDIC RES SO, V12, P265