Amperometric determination of glucose with an MnO2 and glucose oxidase bulk-modified screen-printed carbon ink biosensor

被引:45
作者
Turkusic, E
Kalcher, K
Schachl, K
Komersova, A
Bartos, M
Moderegger, H
Svancara, I
Vytras, K
机构
[1] Graz Univ, Inst Analyt Chem, A-8010 Graz, Austria
[2] Univ Sarajevo, Fac Sci, Dept Chem, Sarajevo 71000, Bosnia & Herceg
[3] Univ Pardubice, Dept Analyt Chem, CZ-53210 Pardubice, Czech Republic
关键词
screen-printed electrode; glucose oxidase; manganese dioxide; flow injection analysis;
D O I
10.1081/AL-100108410
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple biosensor, constructed by bulk-modification of carbon ink with manganese dioxide as a mediator and glucose oxidase as a biocomponent was investigated for its ability to serve as amperometric detector for glucose in hydrodynamic as well as in flow injection analysis (FIA) mode. The sensor could be operated at a potential of 0.48 V under physiological conditions (0.1 M phosphate buffer. pH 7.5) and exhibited excellent reproducibility and stability. Factors influencing the amperometric response such as injection volume, flow rate and applied working potential were studied in detail. The screen-printed electrode exhibited a linear amperometric increase with the concentration of D-glucose from 2 to 2500 mg L-1 and gave a 3 sigma detection limit of 0.085 mg L-1. Due to its remarkable stability such a sensor could be operated continuously for more than four weeks or more than 1000 sample injections. No change of signal height could be observed within an operation period of 12 h. The sensor was exploited for FIA-amperometric determination of glucose in beer and wine samples.
引用
收藏
页码:2633 / 2647
页数:15
相关论文
共 14 条
  • [1] CHEMICAL SENSORS, BIOSENSORS AND THICK-FILM TECHNOLOGY
    GALANVIDAL, CA
    MUNOZ, J
    DOMINGUEZ, C
    ALEGRET, S
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (05) : 225 - 231
  • [2] SELECTIVE DETECTION IN FLOW-ANALYSIS BASED ON THE COMBINATION OF IMMOBILIZED ENZYMES AND CHEMICALLY MODIFIED ELECTRODES
    GORTON, L
    CSOREGI, E
    DOMINGUEZ, E
    EMNEUS, J
    JONSSONPETTERSSON, G
    MARKOVARGA, G
    PERSSON, B
    [J]. ANALYTICA CHIMICA ACTA, 1991, 250 (01) : 203 - 248
  • [3] SCREEN-PRINTED VOLTAMMETRIC AND AMPEROMETRIC ELECTROCHEMICAL SENSORS FOR DECENTRALIZED TESTING
    HART, JP
    WRING, SA
    [J]. ELECTROANALYSIS, 1994, 6 (08) : 617 - 624
  • [4] Janata J, 1998, ANAL CHEM, V70, p179R
  • [5] KALCHER K, 1994, Z ELECTROANALYSIS, V7, P5
  • [6] KALCHER K, 1997, SCI PAP U PARDUBIC A, V3, P57
  • [7] INK-JET PRINTING FOR THE FABRICATION OF AMPEROMETRIC GLUCOSE BIOSENSORS
    NEWMAN, JD
    TURNER, APF
    MARRAZZA, G
    [J]. ANALYTICA CHIMICA ACTA, 1992, 262 (01) : 13 - 17
  • [8] Amperometric determination of hydrogen peroxide with a manganese dioxide film-modified screen printed carbon electrode
    Schachl, K
    Alemu, H
    Kalcher, K
    Moderegger, H
    Svancara, I
    Vytras, K
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (02): : 194 - 200
  • [9] Flow injection determination of hydrogen peroxide using a carbon paste electrode modified with a manganese dioxide film
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    [J]. ANALYTICAL LETTERS, 1997, 30 (15) : 2655 - 2673
  • [10] Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    [J]. ANALYST, 1997, 122 (09) : 985 - 989