Liver segmentation for CT images using GVF snake

被引:108
作者
Liu, F
Zhao, BS
Kijewski, PK
Wang, L
Schwartz, LH
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
关键词
liver contour; image segmentation; GVF; snake; edge map; CT;
D O I
10.1118/1.2132573
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Accurate liver segmentation on computed tomography (CT) images is a challenging task especially at sites where surrounding tissues (e.g., stomach, kidney) have densities similar to that of the liver and lesions reside at the liver edges. We have developed a method for semiautomatic delineation of the liver contours on contrast-enhanced CT images. The method utilizes a snake algorithm with a gradient vector flow (GVF) field as its external force. To improve the performance of the GVF snake in the segmentation of the liver contour, an edge map was obtained with a Canny edge detector, followed by modifications using a liver template and a concavity removal algorithm. With the modified edge map, for which unwanted edges inside the liver were eliminated, the GVF field was computed and an initial liver contour was formed. The snake algorithm was then applied to obtain the actual liver contour. This algorithm was extended to segment the liver volume in a slice-by-slice fashion, where the result of the preceding slice constrained the segmentation of the adjacent slice. 551 two-dimensional liver images from 20 volumetric images with colorectal metastases spreading throughout the livers were delineated using this method, and also manually by a radiologist for evaluation. The difference ratio, which is defined as the percentage ratio of mismatching volume between the computer and the radiologist's results, ranged from 2.9% to 7.6% with a median value of 5.3%. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:3699 / 3706
页数:8
相关论文
共 20 条
[1]
AUTOMATIC SEGMENTATION OF LIVER STRUCTURE IN CT IMAGES [J].
BAE, KT ;
GIGER, ML ;
CHEN, CT ;
KAHN, CE .
MEDICAL PHYSICS, 1993, 20 (01) :71-78
[3]
A methodology for evaluation of boundary detection algorithms on medical images [J].
Chalana, V ;
Kim, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) :642-652
[4]
An automatic diagnostic system for CT liver image classification [J].
Chen, EL ;
Chung, PC ;
Chen, CL ;
Tsai, HM ;
Chang, CI .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (06) :783-794
[5]
ON ACTIVE CONTOUR MODELS AND BALLOONS [J].
COHEN, LD .
CVGIP-IMAGE UNDERSTANDING, 1991, 53 (02) :211-218
[6]
FINITE-ELEMENT METHODS FOR ACTIVE CONTOUR MODELS AND BALLOONS FOR 2-D AND 3-D IMAGES [J].
COHEN, LD ;
COHEN, I .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1993, 15 (11) :1131-1147
[7]
AN ACTIVE CONTOUR MODEL FOR MAPPING THE CORTEX [J].
DAVATZIKOS, CA ;
PRINCE, JL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :65-80
[8]
DETERMINATION OF LIVER VOLUME FROM CT SCANS USING HISTOGRAM CLUSTER-ANALYSIS [J].
FARJO, LA ;
WILLIAMS, DM ;
BLAND, PH ;
FRANCIS, IR ;
MEYER, CR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (05) :674-683
[9]
Automatic liver segmentation technique for three-dimensional visualisation of CT data [J].
Gao, LM ;
Heath, DG ;
Kuszyk, BS ;
Fishman, EK .
RADIOLOGY, 1996, 201 (02) :359-364
[10]
Hong JS, 2001, IEICE T INF SYST, VE84D, P741