PVC-based cobalt and manganese phthalocyanine coated graphite electrodes for determination of thiocyanate

被引:43
作者
Amini, MK [1 ]
Shahrokhian, S [1 ]
Tangestaninejad, S [1 ]
机构
[1] Univ Esfahan, Dept Chem, Esfahan 81744, Iran
关键词
potentiometry; ionophores; thiocyanate selective electrode; cobalt phthalocyanine; manganese phthalocyanine; PVC; graphite rods;
D O I
10.1080/00032719908543002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thiocyanate selective electrodes were prepared by incorporating cobalt and manganese phthalocyanines into plasticized ploy(vinyl chloride) membranes which were directly coated on the surface of graphite electrodes. A calibration plot with Nernstian slope for thiocyanate was observed over a linear range of five decades of concentration (1x10(-6)-1x10(-1) M). The electrode has a fast response time, very low detection limit (5x10(-7) M thiocyanate), is easy to prepare, and could be used for over a month. The proposed sensor revealed good selectivity for thiocyanate over several anions and could be used over a wide pH range. Applications of the electrode to the potentiometric titration of silver ion with thiocyanate and determination of thiocyanate in urine samples are reported.
引用
收藏
页码:2737 / 2750
页数:14
相关论文
共 27 条
[1]   ANION SELECTIVITY OF METALLOPORPHYRINS IN MEMBRANES [J].
AMMANN, D ;
HUSER, M ;
KRAUTLER, B ;
RUSTERHOLZ, B ;
SCHULTHESS, P ;
LINDEMANN, B ;
HALDER, E ;
SIMON, W .
HELVETICA CHIMICA ACTA, 1986, 69 (04) :849-854
[2]  
ARNOLD MA, 1986, ANAL CHEM, V58, pR84
[3]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[4]   MN(III) PORPHYRIN-BASED THIOCYANATE-SELECTIVE MEMBRANE ELECTRODES - CHARACTERIZATION AND APPLICATION IN FLOW-INJECTION DETERMINATION OF THIOCYANATE IN SALIVA [J].
BROWN, DV ;
CHANIOTAKIS, NA ;
LEE, IH ;
MA, SC ;
PARK, SB ;
MEYERHOFF, ME ;
NICK, RJ ;
GROVES, JT .
ELECTROANALYSIS, 1989, 1 (06) :477-484
[5]  
Catrall R.W., 1971, ANAL CHEM, V43, P1905
[6]  
CHANG Q, 1990, AM BIOTECHNOL LAB, V8, P10
[7]   INFLUENCE OF PORPHYRIN STRUCTURE ON ANION SELECTIVITIES OF MANGANESE(III) PORPHYRIN BASED MEMBRANE ELECTRODES [J].
CHANIOTAKIS, NA ;
CHASSER, AM ;
MEYERHOFF, ME ;
GROVES, JT .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :185-188
[8]   POTENTIOMETRIC PHOSPHATE SELECTIVE ELECTRODE BASED ON A MULTIDENDATE TIN(IV) CARRIER [J].
CHANIOTAKIS, NA ;
JURKSCHAT, K ;
RUHLEMANN, A .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :345-352
[9]   ANION-SELECTIVE ELECTRODES BASED ON ELECTROPOLYMERIZED PORPHYRIN FILMS [J].
DAUNERT, S ;
WALLACE, S ;
FLORIDO, A ;
BACHAS, LG .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1676-1679
[10]   VALIDATION OF SELF-REPORTED SMOKING-BEHAVIOR - BIOCHEMICAL ANALYSES OF COTININE AND THIOCYANATE [J].
HALEY, NJ ;
AXELRAD, CM ;
TILTON, KA .
AMERICAN JOURNAL OF PUBLIC HEALTH, 1983, 73 (10) :1204-1207