Analysis of refill liquids for electronic cigarettes

被引:187
作者
Etter, Jean-Francois [1 ]
Zather, Eva [2 ]
Svensson, Sofie [2 ]
机构
[1] Univ Geneva, Fac Med, Inst Social & Prevent Med, CH-1211 Geneva 4, Switzerland
[2] McNeil AB, Analyt Dev R&D, Helsingborg, Sweden
关键词
Electronic cigarette; electronic nicotine delivery systems; nicotine; quality control; smoking; tobacco; NICOTINE DELIVERY-SYSTEMS; USERS; SMOKE;
D O I
10.1111/add.12235
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
Aims To assess levels of nicotine, nicotine degradation products and some specific impurities in commercial refill liquids for electronic cigarettes. Design and setting We analyzed 20 models of 10 of the most popular brands of refill liquids, using gas and liquid chromatography. Measurements We assessed nicotine content, content of the known nicotine degradation products and impurities, and presence of ethylene glycol and diethylene glycol. Findings The nicotine content in the bottles corresponded closely to the labels on the bottles. The levels of nicotine degradation products represented 0-4.4% of those for nicotine, but for most samples the level was 1-2%. Cis-N-oxide, trans-N-oxide, myosmine, anatabine and anabasine were the most common additional compounds found. Neither ethylene glycol nor diethylene glycol were detected. Conclusion The nicotine content of electronic cigarette refill bottles is close to what is stated on the label. Impurities are detectable in several brands above the level set for nicotine products in the European Pharmacopoeia, but below the level where they would be likely to cause harm.
引用
收藏
页码:1671 / 1679
页数:9
相关论文
共 40 条
[1]   Electronic Nicotine Delivery Systems International Tobacco Control Four-Country Survey [J].
Adkison, Sarah E. ;
O'Connor, Richard J. ;
Bansal-Travers, Maansi ;
Hyland, Andrew ;
Borland, Ron ;
Yong, Hua-Hie ;
Cummings, K. Michael ;
McNeill, Ann ;
Thrasher, James F. ;
Hammond, David ;
Fong, Geoffrey T. .
AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2013, 44 (03) :207-215
[2]  
[Anonymous], 2006, ICH TOP Q 3 B R2 IMP
[3]  
[Anonymous], 2006, GOLDFRANKS TOXICOLOG
[4]  
[Anonymous], 2013, PLOS ONE
[5]  
[Anonymous], C SOC RES NIC TOB DU
[6]   Effect of an electronic nicotine delivery device (e cigarette) on desire to smoke and withdrawal, user preferences and nicotine delivery: randomised cross-over trial [J].
Bullen, C. ;
McRobbie, H. ;
Thornley, S. ;
Glover, M. ;
Lin, R. ;
Laugesen, M. .
TOBACCO CONTROL, 2010, 19 (02) :98-103
[7]   Electronic cigarettes as a harm reduction strategy for tobacco control: A step forward or a repeat of past mistakes? [J].
Cahn, Zachary ;
Siegel, Michael .
JOURNAL OF PUBLIC HEALTH POLICY, 2011, 32 (01) :16-31
[8]   Electronic nicotine delivery devices: ineffective nicotine delivery and craving suppression after acute administration [J].
Eissenberg, Thomas .
TOBACCO CONTROL, 2010, 19 (01) :87-88
[9]   Saliva cotinine levels in users of electronic cigarettes [J].
Etter, J-F ;
Bullen, C. .
EUROPEAN RESPIRATORY JOURNAL, 2011, 38 (05) :1219-1220
[10]   Electronic cigarette: users profile, utilization, satisfaction and perceived efficacy [J].
Etter, Jean-Francois ;
Bullen, Chris .
ADDICTION, 2011, 106 (11) :2017-2028