Scan time reduction in proton magnetic resonance spectroscopic imaging of the human brain

被引:30
作者
Golay, X
Gillen, J
van Zijl, PCM
Barker, PB
机构
[1] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Brain Imaging, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
关键词
spectroscopic imaging; scan time reduction; brain; magnetic resonance;
D O I
10.1002/mrm.10038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A simple technique is described for scan time reductions in proton magnetic resonance spectroscopic imaging (MRSI) of the human brain. Scan time is reduced by approximately 35% while preserving spatial resolution by reducing the field of view (FOV) and number of phase-encoding steps in the transverse direction of the brain. A multislice MRSI of the brain is demonstrated which takes approximately 20 min with a square FOV, and 13 min with a reduced FOV. The signal-to-noise ratio (SNR) in the reduced FOV scan was measured to be 15% lower than that of the full FOV scan, which is close to the expected theoretical value of 19% based on the square root of the scan time. The method can be applied with any sequence, and requires minimal software and no hardware modifications. Scan time in MRSI is minimized in this method by using FOVs no larger than the dimensions of the object to be imaged. The method may also be combined with other fast MRSI techniques to provide further scan time reductions. Magn Reson Med 47: 384-387, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:384 / 387
页数:4
相关论文
共 25 条
[1]   Volumetric spectroscopic imaging with spiral-based k-space trajectories [J].
Adalsteinsson, E ;
Irarrazabal, P ;
Topp, S ;
Meyer, C ;
Macovski, A ;
Spielman, DM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :889-898
[2]   ACUTE STROKE - EVALUATION WITH SERIAL PROTON MR SPECTROSCOPIC IMAGING [J].
BARKER, PB ;
GILLARD, JH ;
VANZIJL, PCM ;
SOHER, BJ ;
HANLEY, DF ;
AGILDERE, AM ;
OPPENHEIMER, SM ;
BRYAN, RN .
RADIOLOGY, 1994, 192 (03) :723-732
[3]  
Barker PB, 2000, MAGN RESON MED, V43, P348, DOI 10.1002/(SICI)1522-2594(200003)43:3<348::AID-MRM5>3.0.CO
[4]  
2-M
[5]  
Constantinidis I, 1998, NEUROLOGIST, V4, P77
[6]   Improved proton spectroscopic U-FLARE imaging for the detection of coupled resonances in the rat brain in vivo [J].
Dreher, W ;
Leibfritz, F .
MAGNETIC RESONANCE IMAGING, 1999, 17 (04) :611-621
[7]   FAST PROTON SPECTROSCOPIC IMAGING OF HUMAN BRAIN USING MULTIPLE SPIN-ECHOES [J].
DUYN, JH ;
MOONEN, CTW .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) :409-414
[8]   MULTISECTION PROTON MR SPECTROSCOPIC IMAGING OF THE BRAIN [J].
DUYN, JH ;
GILLEN, J ;
SOBERING, G ;
VANZIJL, PCM ;
MOONEN, CTW .
RADIOLOGY, 1993, 188 (01) :277-282
[9]   Sensitivity-encoded spectroscopic imaging [J].
Dydak, U ;
Weiger, M ;
Pruessmann, KP ;
Meier, D ;
Boesiger, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :713-722
[10]  
ERNST RR, 1987, PRINCIPLES NUCL MAGN, P352