Evaluation of a Novel Spine and Surface Topography System for Dynamic Spinal Curvature Analysis during Gait

被引:40
作者
Betsch, Marcel [1 ]
Wild, Michael [2 ]
Johnstone, Brian [1 ]
Jungbluth, Pascal [3 ]
Hakimi, Mohssen [3 ]
Kuehlmann, Britta [3 ]
Rapp, Walter [4 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Orthopaed & Rehabil, Portland, OR 97201 USA
[2] Klinikum Darmstadt, Dept Trauma & Orthopaed Surg, Darmstadt, Germany
[3] Univ Hosp Duesseldorf, Dept Trauma & Hand Surg, Dusseldorf, Germany
[4] Univ Tubingen Hosp, Dept Sports Med, Tubingen, Germany
关键词
MOIRE TOPOGRAPHY; ANATOMICAL LANDMARKS; BACK SHAPE; X-RAYS; RASTERSTEREOGRAPHY; QUANTIFICATION; DOCUMENTATION; RELIABILITY; DIAGNOSIS; MOVEMENT;
D O I
10.1371/journal.pone.0070581
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Introduction: The assessment of spinal deformities with rasterstereography can enhance the understanding, as well as can reduce the number of x-rays needed. However, to date this technique only allows measurements under static conditions. Since it would be of great value to be able to also analyze the spine in dynamic conditions, the present study evaluated a novel rasterstereographic system. Materials and Methods: A new rasterstereographic device was evaluated in a comparison with the gold standard in motion analysis, the VICON system. After initial testing using 12 flat infrared markers adhered to a solid plate, the two systems were evaluated with the markers adhered onto the backs of 8 test subjects. Four triangles were defined using the markers, and the sides of each triangle were measured under static and dynamic conditions. Results: On the solid plate, the sides of the 4 triangles were measured with a measuring tape and then by the two optical systems. Rasterstereography showed a high accuracy in marker detection on the solid plate. Under dynamic conditions, with the subjects walking on a treadmill, the rasterstereographically-measured side lengths were compared with the lengths measured by the VICON system as an assessment of marker detection. No significant differences (p>0.05) were found between the systems, differing only 0.07-1.1% for all sides of the four triangles with both systems. Discussion: A novel rasterstereographic measurement device that allows surface and spine topography under dynamic conditions was assessed. The accuracy of this system was with one millimeter on a solid plate and during dynamic measurements, to the gold standard for motion detection. The advantage of rasterstereography is that it can be used to determine a three-dimensional surface map and also allows the analysis of the underlying spine.
引用
收藏
页数:8
相关论文
共 33 条
[1]
ADAIR IV, 1977, CLIN ORTHOP RELAT R, P165
[2]
Validating an imaging and analysis system for assessing torso deformities [J].
Ajemba, Peter O. ;
Durdle, Nelson G. ;
Hill, Doug L. ;
Raso, V. James .
COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (03) :294-303
[3]
Asamoah V, 2000, ORTHOPADE, V29, P480, DOI 10.1007/s001320050486
[4]
Reliability and validity of 4D rasterstereography under dynamic conditions [J].
Betsch, Marcel ;
Wild, Michael ;
Jungbluth, Pascal ;
Hakimi, Mohssen ;
Windolf, Joachim ;
Haex, Bart ;
Horstmann, Thomas ;
Rapp, Walter .
COMPUTERS IN BIOLOGY AND MEDICINE, 2011, 41 (06) :308-312
[5]
The risk of carcinogenesis from radiographs to pediatric orthopaedic patients [J].
Bone, CM ;
Hsieh, GH .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2000, 20 (02) :251-254
[6]
OBJECTIVE DETERMINATION OF ANATOMICAL LANDMARKS ON THE BODY-SURFACE - MEASUREMENT OF THE VERTEBRA PROMINENS FROM SURFACE CURVATURE [J].
DRERUP, B ;
HIERHOLZER, E .
JOURNAL OF BIOMECHANICS, 1985, 18 (06) :467-&
[7]
Drerup B, 2001, ORTHOPADE, V30, P242, DOI 10.1007/s001320050603
[8]
Assessment of scoliotic deformity from back shape asymmetry using an improved mathematical model [J].
Drerup, B ;
Hierholzer, E .
CLINICAL BIOMECHANICS, 1996, 11 (07) :376-383
[9]
AUTOMATIC LOCALIZATION OF ANATOMICAL LANDMARKS ON THE BACK SURFACE AND CONSTRUCTION OF A BODY-FIXED COORDINATE SYSTEM [J].
DRERUP, B ;
HIERHOLZER, E .
JOURNAL OF BIOMECHANICS, 1987, 20 (10) :961-970
[10]
MOVEMENT OF THE HUMAN PELVIS AND DISPLACEMENT OF RELATED ANATOMICAL LANDMARKS ON THE BODY-SURFACE [J].
DRERUP, B ;
HIERHOLZER, E .
JOURNAL OF BIOMECHANICS, 1987, 20 (10) :971-977