Multiport well design for sampling of ground water at closely spaced vertical intervals

被引:18
作者
Delin, GN
Landon, MK
机构
[1] U.S. Geological Survey, Mounds View, MN 55112
关键词
D O I
10.1111/j.1745-6584.1996.tb02176.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Detailed vertical sampling is useful in aquifers where vertical mixing is limited and steep vertical gradients in chemical concentrations are expected. Samples can be collected at closely spaced vertical intervals from nested wells with short screened intervals. However, this approach may not be appropriate in all situations. An easy-to-construct and easy-to-install multiport sampling well to collect ground-water samples from closely spaced vertical intervals was developed and tested. The multiport sampling well was designed to sample ground water from surficial sand-and-gravel aquifers. The device consists of multiple stainless-steel tubes within a polyvinyl chloride (PVC) protective casing. The tubes protrude through the wall of the PVC casing at the desired sampling depths. A peristaltic pump is used to collect ground-water samples from the sampling ports. The difference in hydraulic head between any two sampling ports can be measured with a vacuum pump and a modified manometer. The usefulness and versatility of this multiport well design was demonstrated at an agricultural research site near Princeton, Minnesota where sampling ports were installed to a maximum depth of about 12 m below land surface. Tracer experiments were conducted using potassium bromide to document the degree between sampling ports. Samples were successfully collected for analysis of major cations and anions, nutrients, selected herbicides, isotopes, dissolved,eases, and chlorofluorcarbon concentrations.
引用
收藏
页码:1098 / 1104
页数:7
相关论文
共 27 条
  • [1] ALNDON MK, US GEOLOGICAL SURVEY
  • [2] *AM SOC TEST MAT, 1990, D509290 AM SOC TEST
  • [3] Barcelona M.J., 1983, 327 ILL STAT WAT SUR
  • [4] SOME BIASES IN SAMPLING MULTILEVEL PIEZOMETERS FOR VOLATILE ORGANICS
    BARKER, JF
    PATRICK, GC
    LEMON, L
    TRAVIS, GM
    [J]. GROUND WATER MONITORING AND REMEDIATION, 1987, 7 (02) : 48 - 54
  • [5] USING ISOTOPE FRACTIONATION OF NITRATE NITROGEN AND NITRATE OXYGEN FOR EVALUATION OF MICROBIAL DENITRIFICATION IN A SANDY AQUIFER
    BOTTCHER, J
    STREBEL, O
    VOERKELIUS, S
    SCHMIDT, HL
    [J]. JOURNAL OF HYDROLOGY, 1990, 114 (3-4) : 413 - 424
  • [6] Cherry J. A., 1983, AM PETROLEUM I PUBLI
  • [7] MIGRATION OF CONTAMINANTS IN GROUNDWATER AT A LANDFILL - A CASE-STUDY .2. GROUNDWATER MONITORING DEVICES
    CHERRY, JA
    GILLHAM, RW
    ANDERSON, EG
    JOHNSON, PE
    [J]. JOURNAL OF HYDROLOGY, 1983, 63 (1-2) : 31 - 49
  • [8] CLASSEN HC, 1982, 821024 US GEOL SURV
  • [9] GROUNDWATER TRACERS - SHORT REVIEW
    DAVIS, SN
    THOMPSON, GM
    BENTLEY, HW
    STILES, G
    [J]. GROUND WATER, 1980, 18 (01) : 14 - 23
  • [10] DELIN GN, 1994, 944149 US GEOL SURV