Quantitative MR susceptibility mapping using piece-wise constant regularized inversion of the magnetic field

被引:242
作者
de Rochefort, Ludovic [1 ]
Brown, Ryan [1 ]
Prince, Martin R. [1 ]
Wang, Yi [1 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, Cornell Cardiovasc Magnet Resonance Imaging Lab, New York, NY 10021 USA
关键词
magnetic susceptibility quantification; inverse problem; regularization; piece-wise constant;
D O I
10.1002/mrm.21710
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic properties characterized by susceptibility and chemical shift linearly modify the local magnetic field experienced by spins. A piece-wise constant solution using magnetic resonance imaging is found to the challenging inversion problem from field to magnetic properties. The magnetic field shifts were estimated from MR phase images. The MR magnitude images were segmented into many regions of uniform magnetic properties. Standard linear regression using the calculated magnetic field from each region allowed accurate susceptibility quantification. The technique was experimentally validated on a variety of samples including water, vegetable oil, air, Gadolinium, and superparamagnetic iron oxides. Susceptibility was measured with a precision better than 0.1 ppm, in a range of 10 ppm. In vivo feasibility was shown on the forearm for which soft-tissue, cortical bone, and bone marrow susceptibility, and chemical shift values in good agreement with literature data were obtained.
引用
收藏
页码:1003 / 1009
页数:7
相关论文
共 33 条
  • [1] SUSCEPTIBILITY CHANGES FOLLOWING BOLUS INJECTIONS
    ALBERT, MS
    HUANG, W
    LEE, JH
    PATLAK, CS
    SPRINGER, CS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) : 700 - 708
  • [2] [Anonymous], P SIGGRAPH 87
  • [3] Cellular magnetic resonance imaging: current status and future prospects
    Arbab, Ali S.
    Liu, Wei
    Frank, Joseph A.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (04) : 427 - 439
  • [4] OXYGENATION IN THE RABBIT MYOCARDIUM - ASSESSMENT WITH SUSCEPTIBILITY-DEPENDENT MR-IMAGING
    ATALAY, MK
    FORDER, JR
    CHACKO, VP
    KAWAMOTO, S
    ZERHOUNI, EA
    [J]. RADIOLOGY, 1993, 189 (03) : 759 - 764
  • [5] Bernstein MA, 2004, HDB MRI PULSE SEQUEN, P616
  • [6] Magnetic resonance imaging for the determination of magnetic susceptibility of materials
    Beuf, O
    Briguet, A
    Lissac, M
    Davis, R
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 112 (02): : 111 - 118
  • [7] Bjork A, 1996, NUMERICAL METHODS LE, P165
  • [8] MRI measurement of hepatic magnetic susceptibility - Phantom validation and normal subject studies
    Chu, ZL
    Cohen, AR
    Muthupillai, R
    Chung, T
    Wang, ZYJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) : 1318 - 1327
  • [9] DIPOLAR SUMS IN THE PRIMITIVE CUBIC LATTICES
    COHEN, MH
    KEFFER, F
    [J]. PHYSICAL REVIEW, 1955, 99 (04): : 1128 - 1134
  • [10] SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS
    CONTURO, TE
    SMITH, GD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) : 420 - 437