摘要
Evidence for the occurrence of Ni(CO)(4) in addition to Mo(CO)(6) and W(CO)(6) in fermentation gases from a municipal sewage treatment plant is presented for the first time. The gases were sampled at the top of the sewage sludge digester using Tedlar bags, and were analysed using cryotrapping followed by gas chromatography coupled with inductively coupled mass spectrometry (GC-ICP-MS). The use of an ICP-MS as an element-specific detector gives sufficiently low detection limits for metals and was coupled to a packed column gas chromatograph. This method provides information about the speciation of volatile transition metals in contrast to previously used methods for the determination of Ni(CO)(4) in gas samples. The element-specific detection of three different isotopes (m/z 58, 60, 62) and the correspondence of the samples' retention times with those of the standard provided convincing evidence that Ni(CO)(4) is present in the fermentation gas. The concentrations found were in the sub-ppb level, which is at least one order of magnitude lower than the threshold level of 1 ppb (v/v). In addition, Mo(CO)(6) and W(CO)(6) were also measured in the sub-ppb range in contrast to the absence of Fe (CO)(5). The stabilities of Ni(CO)(4), Fe(CO)(5), and Mo(CO)(6) were tested in a carbon monoxide atmosphere. In the presence of distilled water, the following order of stability was found after 11 weeks: Fe(CO)(5) < Ni (CO)(4) < Mo (CO)(6). In the presence of an aqueous solution containing nickel, molybdenum, tungsten and iron, however, only Fe(CO)(5) was significantly decomposed (< 0.3% recovery); Ni(CO)(4) and Mo(CO)(6) were stable after 11 weeks. No W(CO)(6) was formed. The low stability of Fe(CO)(5) in the presence of water could be the reason why no volatile iron compound was found in sewage gas. This study showed that GC-ICP-MS can be employed to identify species-specific traces of metal carbonyIs in process gases such as sewage gas.
引用
收藏
页码:33 / 37
页数:5
相关论文
共 17 条
[1]   UBER METALLCARBONYLE. 661) DIE KOHLENOXYDREAKTIONEN VON NICKEL-UND KOBALTSULFID IM WASSRIG-ALKALISCHEN MEDIUM 1.TEIL [J].
BEHRENS, H ;
EISENMANN, E .
ZEITSCHRIFT FUR ANORGANISCHE UND ALLGEMEINE CHEMIE, 1955, 278 (3-4) :155-1651
[2]   MASS-SPECTROMETRY OF NICKEL CARBONYL FOR MODELING OF AUTOMOBILE CATALYSTS [J].
CAMPANA, JE ;
RISBY, TH .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :468-472
[4]   Summary of a calibration method for the determination of volatile metal(loid) compounds in environmental gas samples by using gas chromatography inductively coupled plasma mass spectrometry [J].
Feldmann, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :1069-1076
[5]   Occurrence of volatile transition metal compounds in landfill gas: Synthesis of molybdenum and Tungsten carbonyls in the environment [J].
Feldmann, J ;
Cullen, WR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (07) :2125-2129
[6]  
FELDMANN J, 1995, THESIS CUVILLIER GOT
[7]  
FILKOVA L, 1986, CHEM LISTY, V80, P1207
[8]  
FILKOVA L, 1986, C HYGENIA, V31, P255
[9]   SPECIES ANALYSIS OF INORGANIC COMPOUNDS IN WORKROOM AIR BY ATOMIC SPECTROSCOPY [J].
Hetland, Siri ;
Martinsen, Ivar ;
Radziuk, Bernard ;
Thomassen, Yngvar .
ANALYTICAL SCIENCES, 1991, 7 :1029-1032
[10]   PORTABLE CHEMI-LUMINESCENCE DETECTOR FOR NICKEL CARBONYL [J].
HIKADE, DA ;
STEDMAN, DH ;
WALEGA, JG .
ANALYTICAL CHEMISTRY, 1984, 56 (09) :1629-1632