Flow-injection solvent extraction with and without phase separation - Fluorimetric determination of aluminium in water

被引:30
作者
Alonso, A [1 ]
Almendral, MJ [1 ]
Porras, MJ [1 ]
Curto, Y [1 ]
de Maria, CG [1 ]
机构
[1] Univ Salamanca, Fac Chem, Dept Quim Analit Nutr & Bromatol, E-37008 Salamanca, Spain
关键词
liquid-liquid extraction; flow-injection; aluminium; water;
D O I
10.1016/S0003-2670(01)01147-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three forms of liquid-liquid extraction in flow-injection systems are compared and applied to the fluorimetric determination of aluminium. after its extraction in chloroform as aluminium oxinate. In the first form, conventional phase segmentation and separation are used. Concentrations of aluminium higher than 6 mug l(-1) can be detected with a linear application range between 20 and 800 mug l(-1), a R.S.D. of 2.8% (50 mug l(-1), n = 10) and a sampling frequency of 20 h(-1). The second form includes phase segmentation, but fluorescence is measured without phase separation. In this mode, aluminium is detected at concentrations higher than 2 mug l-(1) with a linear application range of 10-800 mug l-(1), a R.S.D. of 2.3% (50 mug l-(1), n = 10) and a sampling frequency of 30 h(-1). In the third form, a single segment of organic solution is injected into the aqueous stream and fluorescence is measured without phase separation too. Using this mode, concentrations of aluminium higher than 0.2 mug l-(1) can be detected, with a linear application range between 2 and 120 mug l(-1), a R.S.D. of 4.9% (50 mug l(-1), n = 10) and a sampling frequency of 60 h-(1). All the three forms are applied to the analysis of aluminium in drinking, river and waste water. Under the proposed working conditions, only Fe(III) interferes but this interference is avoided when a mixture of hydroxylamine and o-phenanthroline is added. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 23 条
[1]   CONTINUOUS LIQUID-LIQUID-EXTRACTION FOR PRECONCENTRATION WITH ONLINE MONITORING [J].
AGUDO, M ;
RIOS, A ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2941-2943
[2]   LIQUID LIQUID EXTRACTION IN CONTINUOUS-FLOW SYSTEMS WITHOUT PHASE-SEPARATION [J].
CANETE, F ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2354-2357
[3]   Coupling of flow injection wetting-film extraction without segmentation and phase separation to flame atomic absorption spectrometry for the determination of trace copper in water samples [J].
Chen, HW ;
Liu, JS ;
Mao, XQ .
ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) :151-161
[4]   THE DETERMINATION OF QUICKLY REACTING ALUMINUM IN NATURAL-WATERS BY KINETIC DISCRIMINATION IN A FLOW SYSTEM [J].
CLARKE, N ;
DANIELSSON, LG ;
SPAREN, A .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1992, 48 (02) :77-100
[5]  
COSTADINNOVA L, 1996, ANAL LAB, V5, P46
[6]   EXTRACTION BASED ON FLOW-INJECTION PRINCIPLE .1. DESCRIPTION OF EXTRACTION SYSTEM [J].
KARLBERG, B ;
THELANDER, S .
ANALYTICA CHIMICA ACTA, 1978, 98 (01) :1-7
[7]   ULTRAMICRO SOLVENT-EXTRACTION AND FLUORIMETRY BASED ON FLOW-INJECTION METHOD [J].
KINA, K ;
SHIRAISHI, K ;
ISHIBASHI, N .
TALANTA, 1978, 25 (05) :295-297
[8]   APPLICATION OF A MULTICHANNEL DROPPING DISPENSER IN SEGMENTED CONTINUOUS-FLOW ANALYSIS [J].
KUBAN, V ;
DANIELSSON, LG ;
INGMAN, F .
TALANTA, 1992, 39 (02) :95-99
[9]   DESIGN OF A MULTICHANNEL DROPPING SEGMENTER FOR LIQUID-LIQUID-EXTRACTION CONTINUOUS FLOW-INJECTION ANALYSIS [J].
KUBAN, V ;
INGMAN, F .
ANALYTICA CHIMICA ACTA, 1991, 245 (02) :251-257
[10]   FLOW-INJECTION EXTRACTION WITHOUT PHASE-SEPARATION BASED ON DUAL-WAVELENGTH SPECTROPHOTOMETRY [J].
LIU, HH ;
DASGUPTA, PK .
ANALYTICA CHIMICA ACTA, 1994, 288 (03) :237-245