High-efficiency shock-wave generator for extracorporeal lithotripsy

被引:8
作者
Broyer, P
Cathignol, D
Theillere, Y
Mestas, JL
机构
[1] INSERM U281, 69424 Lyon Cedex 03
[2] University of Luminy, Marseille
[3] Lyon I University, Lyon
关键词
current rise time; discharge line; electro-acoustic efficiency; electrolyte; extracorporeal lithotripsy; shock-wave generator; spark gap; underwater discharge;
D O I
10.1007/BF02519998
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In extracorporeal lithotripsy, the electro-acoustic efficiency of electrohydraulic generators is limited by the inductance of the electrical discharge circuit. A new shock wave generator is described that uses a coaxial discharge line enabling electro-acoustic efficiency to be greatly increased. The line is built using a para-electric ceramic with a relative dielectric constant of 1700, manufactured for use in high-voltage impulse mode. A Coaxial spark gap, with minimal inductance, has been developed to obtain the triggered breakdown of the discharge line. Shock waves are created with a coaxial electrode plugged directly into the spark gap and immersed in an electrolyte of degassed saline. Electrode gap and electrolyte resistivity are adjusted to match the resistivity of the electrolyte volume between the underwater electrodes to the characteristic impedance of the line. The discharge line generates in the medium a rectangular current pulse with an amplitude of about 6000 A and a rise time of 50 ns. Compared with conventional generators, measurements of the expansive peak pressure pulse show an increase of 105% at 10 kV, 86.5% at 12 kV and 34.5% at 14 kV charging voltage. Electro-acoustic efficiency is found to be 11% instead of 5.5% for a conventional discharge circuit.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 22 条
[1]  
BLANCHET M, 1990, S COMM RAP EN EL CLU
[2]   DESIGN AND CHARACTERIZATION OF A SHOCK-WAVE GENERATOR USING CANALIZED ELECTRICAL-DISCHARGE - APPLICATION TO LITHOTRIPSY [J].
BOURLION, M ;
DANCER, P ;
LACOSTE, F ;
MESTAS, JL ;
CATHIGNOL, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (07) :2356-2363
[3]  
BROYER P, 1995, INNOV TECH BIOL MED, V16, P67
[4]   INFLUENCE OF WATER CONDUCTIVITY ON THE EFFICIENCY AND THE REPRODUCIBILITY OF ELECTROHYDRAULIC SHOCK-WAVE GENERATION [J].
CATHIGNOL, D ;
MESTAS, JL ;
GOMEZ, F ;
LENZ, P .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (08) :819-828
[5]  
CATHIGNOL D, 1991, P ULTR 91 INT C, P65
[6]  
Cole R.H., 1948, Underwater Explosions, DOI DOI 10.1063/1.3066176
[7]  
DELIUS M, 1990, FRONTIERS OF NONLINEAR ACOUSTICS, P31
[8]  
EISENBERGER F, 1991, STONE THERAPY UROLOG, P131
[9]   METHOD FOR NO-CONTACT DESTRUCTION OF KIDNEY STONES BY MEANS OF SHOCK-WAVES [J].
FORSSMANN, B ;
HEPP, W ;
CHAUSSY, C ;
EISENBERGER, F ;
WANNER, K .
BIOMEDIZINISCHE TECHNIK, 1977, 22 (7-8) :164-168
[10]  
Gavrilov G. N., 1977, Soviet Physics - Technical Physics, V22, P868