Treatment planning guidelines regarding the use of CT/PET-guided IMRT for cervical carcinoma with positive paraaortic lymph nodes

被引:78
作者
Esthappan, J
Mutic, S
Malyapa, RS
Grigsby, PW
Zoberi, I
Dehdashti, F
Miller, TR
Bosch, WR
Low, DA
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, Dept Radiat Oncol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, Div Nucl Med, St Louis, MO USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 58卷 / 04期
关键词
cervical cancer; paraaortic lymph nodes; positron emission tomography; intensity-modulated radiotherapy; treatment planning;
D O I
10.1016/j.ijrobp.2003.09.074
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Computed tomography (CT)/positron emission tomography (PET)-guided intensity-modulated radiotherapy of the paraaortic lymph nodes (PALNs) has been proposed for patients with cervical carcinoma and paraaortic metastasis. This investigation attempted to determine the guidelines regarding the selection of appropriate treatment parameters (e.g., number of beams, beam geometry) and organ-specific parameters (e.g., importance weighting and tolerance dose) for intensity-modulated radiotherapy planning for the PALNs. Methods and Materials: Patients underwent imaging using CT and PET. The images were registered, and the structures were contoured. A goal dose of 50.4 Gy and 59.4 Gy was assigned to the clinical target volume (lymph node bed) and gross tumor volume (PET-delineated PALNs), respectively. For each patient, multiple treatment plans using various beam geometries and planning parameters were executed and evaluated in terms of the dose-volume histograms of the target and critical structures. Results: Acceptable sparing of the stomach, liver, and colon was achieved, regardless of the number of beams used. Sparing of the spinal cord was strongly dependent on the number and arrangement of the beams. Varying the number and arrangement of the beams affected small intestine sparing, but the amount of sparing was limited because the small intestine overlapped the target volumes, and, therefore, received the prescription dose. Adjusting the number of beams, beam angles, and prescription parameters provided minimal improvement in kidney sparing. Conclusion: We successfully developed treatment plans that deliver 59.4 Gy to the positive PALNs and 50.4 Gy to the paraaortic region using CT/PET-guided intensity-modulated radiotherapy. (C) 2004 Elsevier Inc.
引用
收藏
页码:1289 / 1297
页数:9
相关论文
共 8 条
[1]   A novel approach to overcome hypoxic tumor resistance: Cu-ATSM-guided intensity-modulated radiation therapy [J].
Chao, KSC ;
Bosch, WR ;
Mutic, S ;
Lewis, JS ;
Dehdashti, F ;
Mintun, MA ;
Dempsey, JF ;
Perez, CA ;
Purdy, JA ;
Welch, MJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (04) :1171-1182
[2]   Staging of esophageal cancer with F-18-fluorodeoxyglucose positron emission tomography [J].
Flanagan, FL ;
Dehdashti, F ;
Siegel, BA ;
Trask, DD ;
Sundaresan, SR ;
Patterson, GA ;
Cooper, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (02) :417-424
[3]   Long-term follow-up of RTOG 92-10: Cervical cancer with positive para-aortic lymph nodes [J].
Grigsby, PW ;
Heydon, K ;
Mutch, DG ;
Kim, RY ;
Eifel, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :982-987
[4]   Lymph node staging by positron emission tomography in patients with carcinoma of the cervix [J].
Grigsby, PW ;
Siegel, BA ;
Dehdashti, F .
JOURNAL OF CLINICAL ONCOLOGY, 2001, 19 (17) :3745-3749
[5]   Radiation therapy for carcinoma of the cervix with biopsy-proven positive para-aortic lymph nodes [J].
Grigsby, PW ;
Perez, CA ;
Chao, KSC ;
Herzog, T ;
Mutch, DG ;
Rader, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :733-738
[6]   PET-guided IMRT for cervical carcinoma with positive para-aortic lymph nodes - A dose-escalation treatment planning study [J].
Mutic, S ;
Malyapa, RS ;
Grigsby, PW ;
Dehdashti, F ;
Miller, TR ;
Zoberi, M ;
Bosch, WR ;
Esthappan, J ;
Low, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (01) :28-35
[7]   Multimodality image registration quality assurance for conformal three-dimensional treatment planning [J].
Mutic, S ;
Dempsey, JF ;
Bosch, WR ;
Low, DA ;
Drzymala, RE ;
Chao, KSC ;
Goddu, SM ;
Cutler, PD ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01) :255-260
[8]   Intensity-modulated radiation therapy (IMRT) reduces small bowel, rectum, and bladder doses in patients with cervical cancer receiving pelvic and para-aortic irradiation [J].
Portelance, L ;
Chao, KSC ;
Grigsby, PW ;
Bennet, H ;
Low, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01) :261-266