Role of Triton X-100 in chemiluminescent enzyme immunoassays capable of diagnosing genetic disorders

被引:10
作者
Chong, Richard [1 ]
Rho, Jee-Eun R. [1 ,2 ]
Yoon, Hye-Joo [1 ]
Park, Paul S. [1 ]
Rho, Tae-Ho D. [1 ]
Park, Jee Y. [1 ]
Park, Lucienne [1 ]
Kim, Young-Hwan [1 ]
Lee, Ji Hoon [1 ]
机构
[1] Luminescent MD LLC, Hagerstown, MD 21742 USA
[2] Georgetown Univ, Georgetown Coll, Washington, DC 20057 USA
关键词
Chemiluminescent enzyme immunoassay; Triton X surfactants; Gender disorders; 1,1 '-Oxalyldiimidazole chemilumescence; Peroxyoxalate; CLOUD POINT EXTRACTION;
D O I
10.1016/j.talanta.2013.06.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of Triton X surfactants in developing 1,1'-oxalylimidazole chemiluminescent enzyme immunoassays (ODI CEIs) with extended linear response range for the quantification of unconjugated estriol (uE3), alpha-fetoprotein (AFP), and human chorionic gonadotropin (hCG) is reported for the first time. The wider linear dynamic range in ODI CLEIA results from Triton X series (e.g., Triton X-100, -114, -405, -705) acting as an inhibitor in the interaction between Amplex Red (hydrophobic substrate) and horseradish peroxidase (hydrophilic enzyme) to produce resorufin (hydrophobic fluorescent dye). Triton X-100 acts as the appropriate inhibitor in ODI CLEIA. The maximum concentrations of AFP and hCG quantified with sandwich ODI CLEIA in the presence of Triton X-100 were 8 times higher than when analyzed with the same system in the absence of Triton X-100. In addition, the lowest concentration of uE3 determined using competitive ODI CLEIA in the presence of Triton X-100 was 20 times lower than that measured with competitive ODI CLEIA in the absence of Triton X-100. These results indicate that rapid quantification of AFP, uE3, and hCG using cost effective and highly sensitive ODI CLEIAs in the presence of Triton X-100 can be applied as an accurate, precise, and reproducible method to diagnose genetic disorders (e.g., trisomy 18 and trisomy 21) in fetuses. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:403 / 408
页数:6
相关论文
共 21 条
[1]   Determination of food authenticity by enzyme-linked immunosorbent assay (ELISA) [J].
Asensio, Luis ;
Gonzalez, Isabel ;
Garcia, Teresa ;
Martin, Rosario .
FOOD CONTROL, 2008, 19 (01) :1-8
[2]   Microfluidic immunosensor systems [J].
Bange, A ;
Halsall, HB ;
Heineman, WR .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2488-2503
[3]   Reproducibility of risk figures in 2nd-trimester maternal serum screening for Down syndrome: Comparison of 2 laboratories [J].
Benn, Peter A. ;
Makowski, Gregory S. ;
Egan, James F. X. ;
Wright, Dave .
CLINICAL CHEMISTRY, 2006, 52 (11) :2087-2094
[4]   Speciation Analysis of Silver Nanoparticles and Silver Ions in Antibacterial Products and Environmental Waters via Cloud Point Extraction-Based Separation [J].
Chao, Jing-bo ;
Liu, Jing-fu ;
Yu, Su-juan ;
Feng, Ying-di ;
Tan, Zhi-qiang ;
Liu, Rui ;
Yin, Yong-guang .
ANALYTICAL CHEMISTRY, 2011, 83 (17) :6875-6882
[5]   Roles of CdS quantum dots in 1,1′-oxalyldiimidazole chemiluminescence [J].
Cho, Heejin ;
Lee, Syungju ;
Lee, Ji Hoon .
ANALYST, 2012, 137 (22) :5368-5373
[6]   Rapid quantification of melamine in milk using competitive 1,1′-oxalyldiimidazole chemiluminescent enzyme immunoassay [J].
Choi, JooHee ;
Kim, Young-Teck ;
Lee, Ji Hoon .
ANALYST, 2010, 135 (09) :2445-2450
[7]   1,1′-Oxalyldiimidazole chemiluminescent enzyme immunoassay capable of simultaneously sensing multiple markers [J].
Chong, Richard ;
Rho, Jee-Eun R. ;
Yoon, Hye Joo ;
Rho, Tae-Ho D. ;
Park, Paul S. ;
Kim, Young-Hwan ;
Lee, Ji Hoon .
BIOSENSORS & BIOELECTRONICS, 2012, 32 (01) :19-23
[8]   Chemiluminescence Platforms in Immunoassay and DNA Analyses [J].
Fan, Aiping ;
Cao, Zhijuan ;
Li, Huan ;
Kai, Masaaki ;
Lu, Jianzhong .
ANALYTICAL SCIENCES, 2009, 25 (05) :587-597
[9]   Study of the characteristics of three high-energy intermediates generated in peroxyoxalate chemiluminescence (PO-CL) reactions [J].
Lee, JH ;
Rock, JC ;
Park, SB ;
Schlautman, MA ;
Carraway, ER .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 2002, (04) :802-809
[10]   Advent of innovative chemiluminescent enzyme immunoassay [J].
Lee, Ji Hoon ;
Rho, Jee-Eun R. ;
Rho, Tae-Ho D. ;
Newby, John G. .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :377-382