Determination of the polyfructosan sinistrin in biological fluids by HPLC with electrochemical detection

被引:15
作者
Sechaud, R
Decosterd, LA
PechereBertschi, A
Biollaz, J
Kesselring, UW
机构
[1] UNIV LAUSANNE,PHARM SECT,DEPT PHARMACEUT ANAL,CH-1015 LAUSANNE,SWITZERLAND
[2] UNIV HOSP,DEPT MED,DIV CLIN PHARMACOL,CH-1011 LAUSANNE,SWITZERLAND
[3] UNIV LAUSANNE,POLICLIN MED,CH-1011 LAUSANNE,SWITZERLAND
关键词
polyfructosan; sinistrin; electrochemical detection; ion-moderated partition chromatography; glomerular filtration rater; clearance; renal function;
D O I
10.1016/0731-7085(95)01648-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive HPLC method with electrochemical detection was developed for the determination of the polyfructosan sinistrin in human plasma and urine. Proteins and interfering components such as glucose were removed from plasma and urine samples by solid phase extraction on C-18 cartridges. Chromatogpraphic separations were achieved at 85 degrees C on a 300 mm x 7.8 mm i.d. column, using ion moderated partition chromatography with distilled water at a flow rate of 0.6 ml min(-1). After post-column addition of NaOH 0.3 M (0.6 ml min(-1)), the electrochemical detection of the eluate was performed with a sequence of three potentials (0.05 V, - 0.8 V, 0.6 V) of specific pulse duration 300, 100 and 100 ms respectively. Xylose was used as internal standard for the quantitative determinations. The calibration curves were linear (r(2) > 0.992) over the working range 5-300 mu g ml(-1). This method has been characterized, validated and applied successfully in a study comparing two modes of glomerular filtration rate determination in healthy volunteers (bolus vs. constant rate infusion of sinistrin).
引用
收藏
页码:483 / 490
页数:8
相关论文
共 13 条
[1]   VALIDATION OF BIOANALYTICAL METHODS [J].
KARNES, HT ;
SHIU, G ;
SHAH, VP .
PHARMACEUTICAL RESEARCH, 1991, 8 (04) :421-426
[2]  
Levey AS, 1991, KIDNEY, V1, P919
[3]   OBSERVATIONS ON RENAL CLEARANCE AND VOLUME OF DISTRIBUTION OF POLYFRUCTOSAN-S A NEW INULIN-LIKE SUBSTANCE [J].
MERTZ, DP .
EXPERIENTIA, 1963, 19 (05) :248-&
[4]   MOLECULAR CHARACTERIZATION OF SINISTRIN [J].
NITSCH, E ;
IWANOV, W ;
LEDERER, K .
CARBOHYDRATE RESEARCH, 1979, 72 (JUL) :1-12
[5]  
PRAZNIK WS, 1992, CARBOHYD RES, V243, P91
[6]   REASSESSMENT OF THE SINGLE INTRAVENOUS-INJECTION METHOD WITH INULIN FOR MEASUREMENT OF THE GLOMERULAR-FILTRATION RATE IN MAN [J].
PRESCOTT, LF ;
FREESTONE, S ;
MCAUSLANE, JAN .
CLINICAL SCIENCE, 1991, 80 (02) :167-176
[7]   DETERMINATION OF CARBOHYDRATES BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
ROCKLIN, RD ;
POHL, CA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 (09) :1577-1590
[8]   ASSAY OF INULIN IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
RUO, TI ;
WANG, Z ;
DORDAL, MS ;
ATKINSON, AJ .
CLINICA CHIMICA ACTA, 1991, 204 (1-3) :217-222
[9]  
SCHUMANN L, 1990, CLIN NEPHROL, V33, P35
[10]  
SECHAUD R, 1995, MED WOCHENSCHR S69, V125, pS60