Cardiac stress-rest single-photon emission computed tomography with technetium 99m-labeled tetrofosmin: Influence of washout kinetics on regional myocardial uptake values of the rest study with a 1-day protocol

被引:9
作者
Schulz, G
Ostwald, E
Kaiser, HJ
vomDahl, J
Kleinhans, E
Buell, U
机构
[1] RHEIN WESTFAL TH AACHEN,DEPT NUCL MED,AACHEN,GERMANY
[2] RHEIN WESTFAL TH AACHEN,DEPT INTERNAL MED 1,AACHEN,GERMANY
关键词
technetium 99m-labeled tetrofosmin; emission computed tomography; myocardial scintigraphy; coronary artery disease; washout kinetics;
D O I
10.1016/S1071-3581(97)90107-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to evaluate (1) the washout kinetics of Tc-99m-labeled tetrofosmin, separately for myocardium with normal and reduced perfusion, and (2) its influence on quantitative analysis in a 1-day stress-rest protocol. Methods and Results. Twenty-five patients with angiographically proved coronary artery disease under-went bicycle exercise stress testing with injection of 200 MBq Tc-99m-labeled tetrofosmin and first single-photon emission computed tomographic (SPECT) imaging 40 minutes after injection, A second SPECT was acquired 2.3 +/- 0.4 hours after the first one immediately before rest injection of 800 MBq Tc-99m-labeled tetrofosmin, The rest (third) SPECT was acquired 15 minutes thereafter, The relative washout fraction per time (WOFt) was calculated assuming linear washout kinetics, Thirty-three regional uptake values per study were calculated, normalized to the perfusion maximum (100%) in either the postexercise SPECT and the rest SPECT, for the latter with and without correction of remaining counts from stress injection, In regions with normal perfusion, WOFt was 11.5% +/- 3.5% per hour, In regions with markedly reduced perfusion (relative uptake <50%, WOFt was 8.3% +/- 9.9% per hour, The highest variation of the relative uptake values between rest SPECT with and without correction of remaining counts from stress injection was 5.4% +/- 3.5% in regions with stress-induced ischemia. Conclusion. To use a 1-day protocol with a stress-rest radioactivity ratio of 1:4 and an interval of more than 2 hours between the examinations, a correction for remaining counts from stress injection seems not to be necessary for the quantitative analysis of rest SPECT.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 19 条
[1]   METHOXYISOBUTYLISONITRILE (MIBI) TC-99M SPECT TO ESTABLISH A CORRELATE TO CORONARY FLOW RESERVE, THE PERFUSION RESERVE, FROM GLOBAL AND REGIONAL MYOCARDIAL UPTAKE AFTER EXERCISE AND REST [J].
BUELL, U ;
KAISER, HJ ;
DUPONT, F ;
UEBIS, R ;
KLEINHANS, E ;
HANRATH, P .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (01) :3-9
[2]   TC-99M-METHOXY-ISOBUTYL-ISONITRILE SPECT TO EVALUATE A PERFUSION INDEX FROM REGIONAL MYOCARDIAL UPTAKE AFTER EXERCISE AND AT REST - RESULTS OF A 4 HOUR PROTOCOL IN PATIENTS WITH CORONARY HEART-DISEASE AND IN CONTROLS [J].
BUELL, U ;
DUPONT, F ;
UEBIS, R ;
KAISER, HJ ;
KLEINHANS, E ;
RESKE, SN ;
HANRATH, P .
NUCLEAR MEDICINE COMMUNICATIONS, 1990, 11 (02) :77-94
[3]   MYOCARDIAL KINETICS OF TC-MIBI IN CANINE MYOCARDIUM AFTER DIPYRIDAMOLE [J].
GLOVER, DK ;
OKADA, RD .
CIRCULATION, 1990, 81 (02) :628-637
[4]  
HIGHLEY B, 1993, J NUCL MED, V34, P30
[5]  
HONL K, 1996, NUKLEARMEDIZINER, V35, pA67
[6]   Stress/injection protocols for myocardial scintigraphy with Tc-99(m)-sestamibi compared with Tl-201: Implications of early post-stress kinetics [J].
Hurwitz, GA ;
Blais, M ;
Powe, JE ;
Champagne, CL .
NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (05) :400-409
[7]  
JAIN D, 1993, J NUCL MED, V34, P1254
[8]  
Jones S., 1993, J NUCL MED TECHNOL, V21, P191
[9]   'Reverse redistribution pattern' during myocardial perfusion imaging with Tc-99(m)-MIBI [J].
Kao, CH ;
Wang, SJ ;
Ting, CT ;
Chen, YT .
NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (05) :397-399
[10]  
KELLY JD, 1993, J NUCL MED, V34, P222