Stereoselective determination of ginsenosides Rg3 and Rh2 epimers in rat plasma by LC-MS/MS: Application to a pharmacokinetic study

被引:33
作者
Bae, Soo Hyeon [1 ]
Zheng, Yu Fen [2 ,3 ]
Yoo, Young Hyo [4 ]
Kim, Jeom Yong [4 ]
Kim, Sun Ok [4 ]
Jang, Min Jung [4 ]
Seo, Jae Hong [1 ]
Bae, Soo Kyung [1 ]
机构
[1] Catholic Univ Korea, Coll Pharm, Puchon 420743, Gyeonggi Do, South Korea
[2] Seoul Natl Univ, Coll Pharm, Seoul, South Korea
[3] Seoul Natl Univ, Pharmaceut Sci Res Inst, Seoul, South Korea
[4] Green Cross Herb & Pharmaceut Co Ltd, Songnam, South Korea
关键词
Epimers; Ginsenosides; LC-MS; MS; Pharmacokinetics; Rat plasma; TANDEM MASS-SPECTROMETRY; LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY; SOLID-PHASE EXTRACTION; MURINE MACROPHAGES; GINSENG EXTRACT; IN-VITRO; CELLS; RG(3); STEREOSPECIFICITY; STEREOISOMERS;
D O I
10.1002/jssc.201300107
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
We developed and validated an accurate and sensitive LC-MS/MS method for the simultaneous quantitation of ginsenoside Rg3 and Rh2 epimers (R-Rg3, S-Rg3, R-Rh2, and S-Rh2) in rat plasma. Analytes were extracted from 0.1 mL aliquots of rat plasma by liquid-liquid extraction, using 2 mL of ethyl acetate. In this assay, dioscin (500 ng/mL) was used as an internal standard. Chromatographic separation was conducted using an Acclaim RSLC C18 column (150 x 2.1 mm, 2.2 m) at 40 degrees C, with a gradient mobile phase consisting of 0.1% formic acid in distilled water and in acetonitrile, a flow rate of 0.35 mL/min, and a total run time of 20 min. Detection and quantification were performed using a mass spectrometer in selected reaction-monitoring mode with negative electrospray ionization at m/z 783.4 161.1 for R-Rg3 and S-Rg3, m/z 621.3 161.1 for R-Rh2 and S-Rh2, and m/z 867.2 761.5 for the internal standard. For R-Rg3 and S-Rg3, the lower limit of quantification was 5 ng/mL, with a linear range up to 500 ng/mL; for R-Rh2 and S-Rh2, the lower limit of quantification was 150 ng/mL, with a linear range up to 6000 ng/mL. The coefficient of variation for assay precision was less than 10.5%, with an accuracy of 86.4-112%. No relevant cross-talk or matrix effect was observed. The method was successfully applied to a pharmacokinetic study after oral administration of 400 mg/kg and 2000 mg/kg of BST204, a fermented ginseng extract, to rats. We found that the S epimers exhibited significantly higher plasma concentrations and area under curve values for both Rg3 and Rh2. This is the first report on the separation and simultaneous quantification of R-Rg3, S-Rg3, R-Rh2, and S-Rh2 in rat plasma by LC-MS/MS. The method should be useful in the clinical use of ginseng or its derivatives.
引用
收藏
页码:1904 / 1912
页数:9
相关论文
共 36 条
[1]
[Anonymous], 2012, PLOS ONE
[2]
[Anonymous], CHIN MED
[3]
Ginseng pharmacology - Multiple constituents and multiple actions [J].
Attele, AS ;
Wu, JA ;
Yuan, CS .
BIOCHEMICAL PHARMACOLOGY, 1999, 58 (11) :1685-1693
[4]
Quantitation and pharmacokinetics of 1,4-diamino-2,3-dicyano-1,4-bis (2-aminophenylthio) butadiene (U0126) in rat plasma by liquid chromatography-tandem mass spectrometry [J].
Bae, Soo Hyeon ;
Hwang, Jee Won ;
Shin, Sang Joon ;
Park, Gyu Hwan ;
Yoon, Kee Dong ;
Bae, Soo Kyung .
JOURNAL OF SEPARATION SCIENCE, 2013, 36 (02) :239-245
[5]
Comparison of the pharmacological effects of Panax ginseng and Panax quinquefolium [J].
Chen, Chieh-fu ;
Chiou, Wen-fei ;
Zhang, Jun-tian .
ACTA PHARMACOLOGICA SINICA, 2008, 29 (09) :1103-1108
[6]
Chen X, 2012, J DRUG METAB TOXICOL, V3, P1
[7]
The in Vitro Structure-Related Anti-Cancer Activity of Ginsenosides and Their Derivatives [J].
Dong, Hang ;
Bai, Li-Ping ;
Wong, Vincent Kam Wai ;
Zhou, Hua ;
Wang, Jing-Rong ;
Liu, Yan ;
Jiang, Zhi-Hong ;
Liu, Liang .
MOLECULES, 2011, 16 (12) :10619-10630
[8]
Fei XF, 2002, ACTA PHARMACOL SIN, V23, P315
[9]
Intestinal absorption mechanisms of ginsenoside Rh2: stereoselectivity and involvement of ABC transporters [J].
Gu, Y. ;
Wang, G. -J. ;
Wu, X. -L. ;
Zheng, Y. -T. ;
Zhang, J. -W. ;
Ai, H. ;
Sun, J. -G. ;
Jia, Y. -W. .
XENOBIOTICA, 2010, 40 (09) :602-612
[10]
Quantitative determination of ginsenoside Rh2 in rat biosamples by liquid chromatography electrospray ionization mass spectrometry [J].
Gu, Yi ;
Wang, Guang-Ji ;
Sun, Jian-Guo ;
Jia, Yuan-Wei ;
Xie, Hai-Tang ;
Wang, Wei .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (7-8) :2043-2053