Treatment planning comparison between conformal radiotherapy and helical tomotherapy in the case of locally advanced-stage NSCLC

被引:65
作者
Cattaneo, Giovanni Mauro [1 ]
Dell'Oca, Italo [1 ]
Broggi, Sara [1 ]
Fiorino, Claudio [1 ]
Perna, Lucia [1 ]
Pasetti, Marcella [1 ]
Sangalli, Giulia [1 ]
di Muzio, Nadia [1 ]
Fazio, Ferruccio [1 ]
Calandrino, Riccardo [1 ]
机构
[1] Univ Milano Bicocca, INB CNR, Milan, Italy
关键词
Non-small-cell lung cancer; Radiotherapy; Intensity modulation; Three-dimensional conformal; NTCP;
D O I
10.1016/j.radonc.2008.06.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: To investigate the impact of Helical Tomotherapy (HT) upon the dose distribution when compared to our routinely delivered 3D conformal radiotherapy (CRT) in the case of patients affected by stage III non-small-cell lung cancer (NSCLC). Material and methods: Thirteen stage III inoperable NSCLC patients were scheduled to receive 61.2-70.2 Gy, 1.8 Gy/fraction. Two treatment techniques (HT and CRT) were considered, and in the case of CRT the dose calculation was performed using both the pencil beam (1313) and Anisotropic Analytical Algorithm (AAA) available on the Varian Eclipse planning system. Dose volume constraints for PTV coverage and OAR sparing were assessed for the HT inverse planning with the highest priority upon PTV coverage and spinal cord sparing. The three plans were compared in terms of dose-volume histograms (DVHs) and normal tissue complication probability (NTCP). A statistical analysis was performed using non-parametric Wilcoxon matched pairs tests. Results: In CRT the use of a less accurate algorithm (1313) decreased the monitor unit number by 2.4%. HT significantly improved dose homogeneity within PTV compared with CRT-AAA. For lung parenchyma V20-V40 were lower with HT, corresponding to a decrease of 7% in the risk of radiation pneumonitis. The volume of the heart and esophagus irradiated to >45-60 Gy were reduced using HT plans. For eight PTs with an esophagus-PTV overlap >5%, HT significantly reduced both late and acute esophageal complication probability. Conclusions: Our findings obtained in stage III NSCLC patients underline that HT guarantees an important sparing of lungs and esophagus, thus HT has the potential to improve therapeutic ratio, when compared with CRT, by means of dose escalation and/or combined treatment strategy. In CRT of locally advanced lung cancers, the use of a more advanced algorithm would give significantly better modeling of target dose and coverage. (C) 2008 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 88 (2008) 310-318.
引用
收藏
页码:310 / 318
页数:9
相关论文
共 63 条
[1]  
*AAPM, 2004, 85 AAPM
[2]   Radiation dose escalation in non-small cell carcinoma of the lung [J].
Arriagada, R ;
Komaki, R ;
Cox, JD .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (04) :287-291
[3]   Acute esophageal toxicity in non-small cell lung cancer patients after high dose conformal radiotherapy [J].
Belderbos, J ;
Heemsbergen, W ;
Hoogeman, M ;
Pengel, K ;
Rossi, M ;
Lebesque, J .
RADIOTHERAPY AND ONCOLOGY, 2005, 75 (02) :157-164
[4]   Effects of motion on the total dose distribution [J].
Bortfeld, T ;
Jiang, SB ;
Rietzel, E .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :41-51
[5]   An "in silico" clinical trial comparing free breathing, slow and respiration correlated computed tomography in lung cancer patients [J].
Bosmans, Geert ;
Buijsen, Jeroen ;
Dekker, Andre ;
Velders, Marije ;
Boersma, Liesbeth ;
De Ruysscher, Dirk ;
Minken, Andre ;
Lambin, Philippe .
RADIOTHERAPY AND ONCOLOGY, 2006, 81 (01) :73-80
[6]   Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer [J].
Bradley, J ;
Thorstad, WL ;
Mutic, S ;
Miller, TR ;
Dehdashti, F ;
Siegel, BA ;
Bosch, W ;
Bertrand, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01) :78-86
[7]   Clinical implications of the anisotropic analytical algorithm for IMRT treatment planning and verification [J].
Bragg, Christopher M. ;
Wingate, Katrina ;
Conway, John .
RADIOTHERAPY AND ONCOLOGY, 2008, 86 (02) :276-284
[8]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[9]   Response, toxicity, failure patterns, and survival in five radiation therapy oncology group (RTOG) trials of sequential and/or concurrent chemotherapy and radiotherapy for locally advanced non-small-cell carcinoma of the lung [J].
Byhardt, RW ;
Scott, C ;
Sause, WT ;
Emami, B ;
Komaki, R ;
Fisher, B ;
Lee, JS ;
Lawton, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :469-478
[10]  
Ceresoli GL, 2007, TUMORI J, V93, P88