Determination of iodine in food-related certified reference materials using wet ashing and detection by inductively coupled plasma mass spectrometry

被引:102
作者
Larsen, EH
Ludwigsen, MB
机构
[1] National Food Agency of Denmark, Inst. of Food Chem. and Nutrition, DK-2860 Søborg
关键词
iodine; food; certified reference materials; sample introduction; inductively coupled plasma mass spectrometry; signal enhancement; NEUTRON-ACTIVATION ANALYSIS; ISOTOPE-DILUTION; NANOGRAM AMOUNTS; MILK POWDER;
D O I
10.1039/a607581i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Iodine was accurately determined in food-related certified reference materials (CRMs) by wet ashing in closed steel bombs using a mixture of nitric acid and perchloric acid followed by measurement of iodine by ICP-MS at m/z 127. The iodine concentrations determined were 0.15-4.59 mu g g(-1) (dry mass). Potentially volatile iodine species such as hydrogen iodide were converted during the ashing procedure to nonvolatile species, Hereby memory problems in the ICP-MS due to volatile iodine were prevented, The concentric nebulizer which was used in combination with a low dead-volume cyclonic spray chamber improved the iodine signal intensity and reduced the wash-out time between samples compared with the standard Ryton double-pass spray chamber equipped with a cross flow nebulizer, Iodine contamination from the PTFE liners of the bombs led to blank values at an average of 9 ng per ashing, The limit of detection which was based on three standard deviations of the blank was 30 ng g(-1) (dry mass), By adding 3% v/v methanol to the analyte solutions and increasing the plasma power to 1200 W, the signal-to-noise ratio and hence the limit of detection was improved by 50% due to the signal enhancement effect by carbon of the incompletely ionized iodine.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 22 条
[1]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[2]   DETERMINATION OF IODINE AND BROMINE IN PLASMA AND URINE BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
MAURAS, Y ;
DOUGE, C ;
JAUNAULT, L ;
DELAPORTE, T ;
BEAUGRAND, C .
ANALYST, 1990, 115 (06) :813-815
[3]   RAPID AND SENSITIVE DETERMINATION OF IODINE IN FRESH MILK AND MILK POWDER BY INDUCTIVELY COUPLED PLASMA - MASS-SPECTROMETRY (ICP-MS) [J].
BAUMANN, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (07) :809-812
[4]   IODINE IN DIFFERENT FOOD ARTICLES AND STANDARD REFERENCE MATERIALS [J].
DERMELJ, M ;
SLEJKOVEC, Z ;
BYRNE, AR ;
STEGNAR, P ;
STIBILJ, V ;
ROSSBACH, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (04) :559-561
[5]   DETERMINATION OF IODINE IN OYSTER TISSUE BY ISOTOPE-DILUTION LASER RESONANCE IONIZATION MASS-SPECTROMETRY [J].
FASSETT, JD ;
MURPHY, TJ .
ANALYTICAL CHEMISTRY, 1990, 62 (04) :386-389
[6]  
FISCHER PWF, 1986, J ASSOC OFF ANA CHEM, V69, P687
[7]  
FREY H, 1995, IODIEN RISK EVALUATI, P119
[8]   DETERMINATION OF TRACE LEVEL IODINE IN BIOLOGICAL AND BOTANICAL REFERENCE MATERIALS BY ISOTOPE-DILUTION MASS-SPECTROMETRY [J].
GRAMLICH, JW ;
MURPHY, TJ .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1989, 94 (04) :215-220
[9]   IODINE TRACE DETERMINATION BY NEGATIVE THERMAL IONIZATION MASS-SPECTROMETRY - ANALYSIS OF TABLE SALTS AND COMPARISON WITH RESULTS BY AN ION-SELECTIVE ELECTRODE [J].
HEUMANN, KG ;
SCHINDLMEIER, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 312 (07) :595-599
[10]   DETERMINATION OF IODINE IN FOODS BY CATHODIC STRIPPING VOLTAMMETRY [J].
HOLAK, W .