In vivo confocal Raman spectroscopy of the human cornea

被引:27
作者
Bauer, NJC [1 ]
Hendrikse, F [1 ]
March, WF [1 ]
机构
[1] Acad Ziekenhuis Maastricht, Dept Ophthalmol, NL-6202 AZ Maastricht, Netherlands
关键词
Raman spectroscopy; confocal; cornea; corneal hydration; human;
D O I
10.1097/00003226-199907000-00015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To investigate the feasibility of a confocal Raman spectroscopic technique (see ref. 13) for the noninvasive assessment of corneal hydration in vivo in two legally blind subjects. Methods. A laser beam (632.8 nm; 15 mJ) was maintained on the cornea by using a microscope objective lens (x25 magnification, NA = 0.5, f = 10 mm) both for focusing the incident light as well as collecting the Raman backscattered light, in a 180 degrees backscatter configuration. An optical fiber, acting as the confocal pinhole for elimination of light from out-of-focus places, was coupled to a spectrometer that dispersed the collected light onto a sensitive array detector for rapid spectral data acquisition over a range from 2,890 to 3.590/cm(-1) Raman spectra were recorded from the anterior 100-150 mu m of the cornea over a period before and after topical application of a mild dehydrating solution. The ratio between the amplitudes of the signals at 3,400/cm(-1) (OH-vibrational mode of water) and 2,940/cm(-1) (CH-vibrational mode of proteins) was used as a measure for corneal hydration. Results, High signal-to-noise ratio (SNR = 25) Raman spectra were obtained from the human corneas by using 15 mJ of laser light energy. Qualitative changes in the hydration of the anteriormost part of the corneas could be observed as a result of the dehydrating agent. Conclusion, With adequate improvements in system safety, confocal Raman spectroscopy could potentially be applied clinically as a noninvasive tool for the assessment of corneal hydration in vivo.
引用
收藏
页码:483 / 488
页数:6
相关论文
共 22 条
[1]  
*AM NAT STAND I, 1993, Z1361 ANSI LAS I AM, P28
[2]  
Bauer NJC, 1998, INVEST OPHTH VIS SCI, V39, P831
[3]  
BAUER NJC, IN PRESS J OCUL PHAR
[4]   EXCIMER-LASER ABLATION RATE AND CORNEAL HYDRATION [J].
DOUGHERTY, PJ ;
WELLISH, KL ;
MALONEY, RK .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (02) :169-176
[5]  
Erckens RJ, 1997, J RAMAN SPECTROSC, V28, P293, DOI 10.1002/(SICI)1097-4555(199705)28:5<293::AID-JRS47>3.0.CO
[6]  
2-0
[7]   EFFECT OF CORNEAL EDEMA UPON THE SMOOTHNESS OF EXCIMER-LASER ABLATION [J].
FIELDS, CR ;
TAYLOR, SM ;
BARKER, FM .
OPTOMETRY AND VISION SCIENCE, 1994, 71 (02) :109-114
[8]   RAMAN-SCATTERING OF COLLAGEN, GELATIN, AND ELASTIN [J].
FRUSHOUR, BG ;
KOENIG, JL .
BIOPOLYMERS, 1975, 14 (02) :379-391
[9]   RAMAN-SPECTROSCOPY OF INTACT FELINE CORNEAL COLLAGEN [J].
GOHEEN, SC ;
LIS, LJ ;
KAUFFMAN, JW .
BIOCHIMICA ET BIOPHYSICA ACTA, 1978, 536 (01) :197-204
[10]  
HERSE P, 1992, ACTA OPHTHALMOL, V70, P740