Computing patient doses of x-ray examinations using a patient size- and sex-adjustable phantom

被引:41
作者
Rannikko, S
Ermakov, I
Lampinen, JS
Toivonen, M
Karila, KTK
Chervjakov, A
机构
[1] FINNISH CTR RADIAT & NUCL SAFETY,FIN-00881 HELSINKI,FINLAND
[2] UNIV HELSINKI,INST BIOMED,FIN-00014 HELSINKI,FINLAND
[3] MINIST HLTH,CENT SCI INST RADIOL & ROENTGENOL,ST PETERSBURG,RUSSIA
[4] UNIV HELSINKI,DEPT PHYS,FIN-00014 HELSINKI,FINLAND
关键词
D O I
10.1259/bjr.70.835.9245883
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Both the use of traditional fluoroscopy and the increasing use of modern digital techniques in radiology and interventional radiology demand the development of versatile computer programs for patient dose determinations. Long computing times restrict the use of Monte Carlo (MC) methods in dose monitoring applications where the radiological views change frequently. In the Organ Doses Calculation Software application (ODS-60), the phantom model is similar in principle to the Alderson-Rando (A-R) phantom, but its sex! size and shape is modified according to a particular patient. Organ and effective doses are computed online (in a few seconds) using a method similar to the traditional dose planning systems used in radiotherapy. In this paper, the new ODS-60 software is presented in detail and its capabilities are demonstrated. Software performance was determined by comparing the results with those from independent methods. In the case of a reference man-sized male, the effective dose was about 7% larger than the effective dose given in another publication. In the case of a reference woman-sized female, the disagreement with the other method was greater (33%). Anatomical differences between the phantom models (ODS-60 and MC) were found to be the main reasons for these findings. This paper shows the advantage of using a patient size- and sex-adaptable phantom for patient dose determinations; the conversion coefficient from entrance surface dose-to-effective dose ratio between male (170 cm, 85 kg) and a female (160 cm, 43 kg) varies in the range 1.5-2.
引用
收藏
页码:708 / 718
页数:11
相关论文
共 32 条
[1]  
[Anonymous], 1982, S885 GSF
[2]  
[Anonymous], 1993, 3093 GSF
[3]  
[Anonymous], 1993, SOURC EFF ION RAD
[4]  
BIRCH R, 1979, CATALOGUE SPECTRAL D
[5]  
*COMM EUR COMM, 1990, XII7390 COMM EUR COM
[6]  
CRISTY M, 1980, NUREGCR1159 ORNL
[7]  
Day M J, 1983, Br J Radiol Suppl, V17, P105
[8]  
DREXLER G, 1989, RADIAT PROT DOSIM, V28, P181
[9]   DEPENDENCE OF THE PHOTON BACKSCATTER FACTOR FOR WATER ON SOURCE-TO-PHANTOM DISTANCE AND IRRADIATION FIELD SIZE [J].
GROSSWENDT, B .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1233-1245
[10]   ESTIMATION OF EFFECTIVE DOSE FROM DOSE-AREA PRODUCT MEASUREMENTS FOR BARIUM MEALS AND BARIUM ENEMAS [J].
HART, D ;
WALL, BF .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) :485-489