Comparison of two methods for selecting minimum stimulation levels used in programming the nucleus 22 cochlear implant

被引:58
作者
Skinner, MW
Holden, LK
Holden, TA
Demorest, ME
机构
[1] Washington Univ, Sch Med, Dept Otolaryngol Head & Neck Surg, St Louis, MO 63110 USA
[2] Univ Maryland, Baltimore, MD 21201 USA
来源
JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH | 1999年 / 42卷 / 04期
关键词
cochlear implant; speech processor program; minimum stimulation levels; speech recognition;
D O I
10.1044/jslhr.4204.814
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Minimum stimulation levels for active electrodes in a Nucleus 22 cochlear implant were set at threshold (clinical default value) and raised levels (M = +2.04 dB) to determine if raised levels would improve recipients' understanding of soft speech sounds with the SPEAK speech coding strategy. Eight postlinguistically deaf adults participated in a 4-phase A(1)B(1)A(2)B(2) test design. Speech recognition was evaluated with consonant-vowel nucleus-consonant (CNC) words in quiet and sentences in noise, both presented at 50, 60, and 70 dB SPL during 2 weekly sessions at the end of each phase. Group mean scores were significantly higher with the raised level program for words and phonemes at 50 and 60 dB SPL and for sentences at 50 and 70 dB SPL. All participants chose to use the raised level program in everyday life at the end of the study The results suggest that clinical use of a raised level program for Nucleus 22 recipients has the potential to make soft sounds louder and, therefore, more salient in everyday life. Further research is needed to determine if this approach is appropriate for other cochlear implant devices.
引用
收藏
页码:814 / 828
页数:15
相关论文
共 19 条
[1]  
ANSI, 1969, S351969 ANSI
[2]   VOICE FUNDAMENTAL-FREQUENCY AS AN AUDITORY SUPPLEMENT TO THE SPEECHREADING OF SENTENCES [J].
BOOTHROYD, A ;
HNATHCHISOLM, T ;
HANIN, L ;
KISHONRABIN, L .
EAR AND HEARING, 1988, 9 (06) :306-312
[3]   PREFERRED METHOD FOR CLINICAL DETERMINATION OF PURE-TONE THRESHOLDS [J].
CARHART, R ;
JERGER, JF .
JOURNAL OF SPEECH AND HEARING DISORDERS, 1959, 24 (04) :330-345
[4]  
CLARK GM, 1987, ADV OTORHINOLARYNGOL, V38, P1
[5]  
*COCHL CORP, 1993, MIN 22 AUD HDB
[6]  
*COCHL LTD, 1996, DIAGN PROGRM SOFTW V
[7]   COMPOSITE SPEECH SPECTRUM FOR HEARING-AID GAIN PRESCRIPTIONS [J].
COX, RM ;
MOORE, JN .
JOURNAL OF SPEECH AND HEARING RESEARCH, 1988, 31 (01) :102-107
[8]  
Pearsons K. S., 1976, SPEECH LEVELS VARIOU
[9]   REVISED CNC LISTS FOR AUDITORY TESTS [J].
PETERSON, GE ;
LEHISTE, I .
JOURNAL OF SPEECH AND HEARING DISORDERS, 1962, 27 (01) :62-70
[10]  
Seligman P., 1995, Annals of Otology Rhinology and Laryngology, V104, P172