Isotropic resolution diffusion tensor imaging with whole brain acquisition in a clinically acceptable time

被引:150
作者
Jones, DK
Williams, SCR
Gasston, D
Horsfield, MA
Simmons, A
Howard, R
机构
[1] Inst Psychiat, Old Age Psychiat Sect, London SE5 8AF, England
[2] Leicester Royal Infirm, Div Med Phys, Leicester, Leics, England
[3] Inst Psychiat, Neuroimaging Res Grp, London, England
[4] Inst Psychiat, Dept Psychol, Res Sect, London SE5 8AF, England
基金
英国惠康基金;
关键词
MRI; diffusion; tensor; anisotropy; isotropic resolution; tractography; sequence; protocol;
D O I
10.1002/hbm.10018
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Our objective was to develop a diffusion tensor MR imaging pulse sequence that allows whole brain coverage with isotropic resolution within a clinically acceptable time. A single-shot, cardiac-gated MR pulse sequence, optimized for measuring the diffusion tensor in human brain, was developed to provide whole-brain coverage with isotropic (2.5 x 2.5 x 2.5 mm) spatial resolution, within a total imaging time of approximately 15 min. The diffusion tensor was computed for each voxel in the whole volume and the data processed for visualization in three orthogonal planes. Anisotropy data were further visualized using a maximum-intensity projection algorithm. Finally, reconstruction of fiber-tract trajectories i.e., 'tractography' was performed. Images obtained with this pulse sequence provide clear delineation of individual white matter tracts, from the most superior cortical regions down to the cerebellum and brain stem. Because the data are acquired with isotropic resolution, they can be reformatted in any plane and the sequence can therefore be used, in general, for macroscopic neurological or psychiatric neuroimaging investigations. The 3D visualization afforded by maximum intensity projection imaging and tractography provided easy visualization of individual white matter fasciculi, which may be important sites of neuropathological degeneration or abnormal brain development. This study has shown that it is possible to obtain robust, high quality diffusion tensor MR data at 1.5 Tesla with isotropic resolution (2.5 x 2.5 x 2.5 mm) from the whole brain within a sufficiently short imaging time that it may be incorporated into clinical imaging protocols. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:216 / 230
页数:15
相关论文
共 87 条
  • [1] Atkinson D, 2000, MAGN RESON MED, V44, P101, DOI 10.1002/1522-2594(200007)44:1<101::AID-MRM15>3.0.CO
  • [2] 2-S
  • [3] Comparative MR imaging study of brain maturation in kittens with T1, T2, and the trace of the diffusion tensor
    Baratti, C
    Barnett, AS
    Pierpaoli, C
    [J]. RADIOLOGY, 1999, 210 (01) : 133 - 142
  • [4] Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
  • [5] 2-O
  • [6] Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
  • [7] ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03): : 247 - 254
  • [8] BASSER PJ, 1995, 3 ANN M INT SOC MAGN, V2, P900
  • [9] BASSER PJ, 1998, 6 ANN M INT SOC MAGN, V2, P1226
  • [10] The use of diffusion tensor imaging in quantifying the effect of dexamethasone on brain tumours
    Bastin, ME
    Delgado, M
    Whittle, IR
    Cannon, J
    Wardlaw, JM
    [J]. NEUROREPORT, 1999, 10 (07) : 1385 - 1391