Improving the beam quality of the neutron radiography facility using the SLOWPOKE-2 at the Royal Military College of Canada

被引:4
作者
Lewis, WJ
Bennett, LGI
Teshima, P
机构
[1] Dept. of Chem. and Chem. Engineering, Royal Military College of Canada, Kingston
关键词
D O I
10.1016/0168-9002(96)00113-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the SLOWPOKE-2 Facility at the Royal Military College of Canada, a neutron radiography facility has been designed and installed, and the beam quality has been improved by performing a series of radiographs using American Standard for Testing and Materials (ASTM) E 545 indicators. Other means of determining the progress such as bubble detectors and activation foils were used. Modifications to the nosepiece of the beam tube including shielding and linings for fast neutron and gamma radiation were made.
引用
收藏
页码:41 / 44
页数:4
相关论文
共 7 条
[1]  
ANDREWS WS, 1989, THESIS DEP CHEM CHEM
[2]  
*ASTM, 1981, STAND METH DET IM QU
[3]   THE MULTI-ROLE NATURE OF THE SLOWPOKE-2 FACILITY AT THE ROYAL-MILITARY-COLLEGE-OF-CANADA [J].
BENNETT, LGI ;
BEELEY, PA .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1994, 180 (02) :339-345
[4]  
Domanus J.C., 1992, Practical Neutron Radiography
[5]  
LEWIS WJ, 1989, P 3 WORLD C OS JAP M
[6]  
LEWIS WJ, 1988, THESIS DEP CHEM CHEM
[7]  
TUME P, 1996, P RAD PROT SHIELD TO