Comparison of direct alpha spectrometry and neutron activation analysis of aerosol filters for determination of workplace thorium air concentrations

被引:15
作者
Hotzl, H [1 ]
Riedmann, W [1 ]
Weinmuller, K [1 ]
Winkler, R [1 ]
机构
[1] OSRAM GMBH, ABT STRAHLENSCHUTZ & ISOPENTECH, D-81536 MUNICH, GERMANY
来源
HEALTH PHYSICS | 1996年 / 70卷 / 05期
关键词
thorium; monitoring; personnel; spectrometry; alpha; ionization chambers;
D O I
10.1097/00004032-199605000-00005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Direct alpha spectrometry with three different filter types was investigated for the determination of thorium air concentrations at workplaces in the manufacturing process of discharge lamps containing thoriated tungsten electrodes, The method was compared with neutron activation analysis over an activity range of five orders of magnitude, Within the experimental limits of error, both methods were found to be comparable with respect to sensitivity and accuracy, The advantage of direct alpha spectrometry, however, is that it is less laborious than neutron activation analysis and that it supplies information on the degree of radioactive equilibrium of the thorium series, which is important with regard to the estimation of dose.
引用
收藏
页码:651 / 655
页数:5
相关论文
共 20 条
[1]  
[Anonymous], 1979, ICRP PUBLICATION, V30
[2]  
BERTHOLD F, 1967, IAEASM9536, P597
[3]   DETECTION LIMIT CONCEPTS - FOUNDATIONS, MYTHS, AND UTILIZATION [J].
CHAMBLESS, DA ;
DUBOSE, SS ;
SENSINTAFFAR, EL .
HEALTH PHYSICS, 1992, 63 (03) :338-340
[4]  
DEHOS R, 1993, BFSISH16193, P115
[5]  
DILGER H, 1993, BFSISH16193 BER, P76
[6]  
Gilbert R., 1987, STAT METHODS ENV POL, P217
[7]   THORIUM METABOLISM AND BIOASSAY OF MINERAL SANDS WORKERS [J].
HEWSON, GS ;
FARDY, JJ .
HEALTH PHYSICS, 1993, 64 (02) :147-156
[9]  
HOTZL H, 1978, S474 GSF
[10]  
ICRP, 1991, ANN ICRP, V21, P1