Rotational acetabular osteotomy using biodegradable internal fixation

被引:19
作者
Nakamura, S [1 ]
Takatori, Y [1 ]
Morimoto, S [1 ]
Umeyama, T [1 ]
Yamamoto, M [1 ]
Moro, T [1 ]
Ninomiya, S [1 ]
机构
[1] Univ Tokyo, Fac Med, Dept Orthopaed Surg, Tokyo 113, Japan
关键词
D O I
10.1007/s002640050333
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We used biodegradable poly-L-lactide screws in rotational acetabular osteotomy in 41 hips of 41 patients, and studied the complications after an average follow-up of 4.9 years (range 1.0-7.7 years). There were 39 females and 2 males, their average age at the time of the operation was 32 years (range 12-55 years). A small subcutaneous abscess appeared around the non-absorbable sutures in 2 patients after surgery, There was 1 case of thrombophlebitis and 1 of local dermatitis. The small subcutaneous abscess resolved after the removal of the suture material in the 2 cases, and the thrombophlebitis resolved with aspirin. The local dermatitis persisted but was cured by local steroid therapy over 5.8 years. The incidence of local dermatitis after the use of biodegradable implants should be further investigated.
引用
收藏
页码:148 / 149
页数:2
相关论文
共 6 条
[1]   SEVERE ASEPTIC SYNOVITIS OF THE KNEE AFTER BIODEGRADABLE INTERNAL-FIXATION - A CASE-REPORT [J].
FRIDEN, T ;
RYDHOLM, U .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :94-97
[2]   POLYLACTIDE SCREWS IN ACETABULAR OSTEOTOMY - 28 DYSPLASTIC HIPS FOLLOWED FOR 1 YEAR [J].
NAKAMURA, S ;
NINOMIYA, S ;
TAKATORI, Y ;
MORIMOTO, S ;
KUSABA, I ;
KUROKAWA, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (03) :301-302
[3]   ROTATIONAL ACETABULAR OSTEOTOMY FOR THE DYSPLASTIC HIP [J].
NINOMIYA, S ;
TAGAWA, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (03) :430-436
[4]  
Tuompo P, 1997, INT ORTHOP, V21, P355
[5]  
WELLER A, 1996, J BONE JOINT SURG BR, V78, P369
[6]  
YAMAMURO T, 1994, INT ORTHOP, V18, P332