Effects of carbon in negative plates on cycle-life performance of valve-regulated lead/acid batteries

被引:133
作者
Shiomi, M
Funato, T
Nakamura, K
Takahashi, K
Tsubota, M
机构
[1] Lead-Acid Battery Laboratory, Japan Storage Battery Co., Ltd., Kyoto 601, Nishinosho, Kisshoin, Minami-ku
关键词
lead/acid batteries; negative plates; carbon; cycle performance;
D O I
10.1016/S0378-7753(96)02515-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 [物理化学]; 081704 [应用化学];
摘要
Increasing amounts of carbon in the negative plates of valve-regulated lead/acid batteries reduced the PbSO4 accumulation and extended the life performance in the simulated cycle-life test using the operational pattern of hybrid electric vehicles and photovoltaic power systems. It improved also the rechargeability of large batteries and cycle-life performance when operated in the condition of a small overcharge. Carbon formed a conductive network on PbSO4 particles of the discharged negative plates.
引用
收藏
页码:147 / 152
页数:6
相关论文
共 8 条
[1]
BODE H, 1977, LEAD ACID BATTERIES, P336
[2]
FAILURE MODES OF LEAD-ACID-BATTERIES [J].
CULPIN, B ;
RAND, DAJ .
JOURNAL OF POWER SOURCES, 1991, 36 (04) :415-438
[3]
FUNATO T, 1993, GS NEWS TECH REP, V52, P21
[4]
KOIKE T, 1995, GS NEWS TECH REP, V54, P6
[6]
RICHTER G, 1993, J POWER SOURCES, V46, P191
[7]
SHIMPO M, 1990, YUASA JIHO, V68, P26
[8]
TAKAHASHI, 1985, GS NEWS TECH REP, V44, P8